69
Electrical installation
Type 8098 FLOWave L
8.16
Knowing the status of the Ethernet network (device
variant with two 4-pin M12 female connectors –
Ethernet device variant)
The status of the Ethernet network is indicated by LEDs. The LEDs are located on the industrial communi
-
cation module in the transmitter housing.
→
To see the LEDs, open the front of the transmitter housing by removing either the blind cover or the
display module or the Wi-Fi module; see chapter
Interface X2
(Ethernet Port Switch):
Link/Act LED (green)
Link LED (yellow)
Connection to the PLC:
Error LED (yellow)
RUN LED (green)
X1
X2
Interface X1
(Ethernet Port Switch):
Link LED (yellow)
Link/Act LED (green)
Fig. 35:
Status LEDs for the industrial communication module
Description of the LEDs:
Table 17:
Status LED for the connection to the PLC
LED status
Connection status
What to do?
RUN LED (green)
Error LED (yellow)
ON
OFF
Connection active.
-
OFF
ON
Connection not active.
Check cables
Table 18:
Status LEDs for the connection to the Ethernet network
LED status
Connection status
What to do?
Link/Act
LED
(green)
ON
Rapid flashing: connection to the higher-level pro
-
tocol layer EtherNet/IP has been established. Data
is being transmitted.
Slow flashing: there is no connection to the pro
-
tocol layer. This is usually the case for approx.
20 seconds following a restart.
-
OFF
No connection to the network is available.
Check cables
Link LED
(yellow)
ON
Connection to the network is available.
-
OFF
No connection to the network is available.
Check cables
English
Содержание Flowave 8098
Страница 1: ...Operating Instructions Type 8098 FLOWave L SAW Flowmeter Software version A 04 00 00 and higher...
Страница 4: ...General contents 4 Type 8098 FLOWave L English...
Страница 12: ...12 Type 8098 FLOWave L English...
Страница 36: ...36 Technical data Type 8098 FLOWave L English...
Страница 72: ...72 Type 8098 FLOWave L English...
Страница 78: ...78 Commissioning Type 8098 FLOWave L English...
Страница 96: ...96 Type 8098 FLOWave L English...
Страница 144: ...144 Type 8098 FLOWave L English...
Страница 248: ...248 Type 8098 FLOWave L English...
Страница 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Страница 304: ...304 Type 8098 FLOWave L English...
Страница 316: ...316 Type 8098 FLOWave L English...
Страница 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Страница 352: ...352 Appendix Type 8098 FLOWave L English...
Страница 353: ......
Страница 354: ...www burkert com...