22
Technical data
Type 8098 FLOWave L
6
TECHNICAL DATA
6.1
Operating conditions
Ambient temperature
Depends on the liquid temperature (see
)
• Device variant with two
M20x1.5 cable glands and
one 5-pin M12 connector
•
–10 °C...+70 °C, if the liquid temperature is –10 °C...+80 °C (see Fig. 9
)
• See
Fig. 9, if the liquid temperature is higher than +80 °C
• Device variant with two 4-pin
M12 female connectors and
one 5-pin M12 connector
(Ethernet device variant)
•
)
Air humidity
< 85 %, non condensing
Height above see level
max. 2000 m
Operating conditions
Continuous operation
Equipment mobility
Fixed device
Use
Indoor and outdoor
▶
Protect the device against electromagnetic interference, ultraviolet rays
and, when installed outdoors, against the effects of climatic conditions.
Installation category
Category I according to UL/EN 61010-1
Degree of pollution
Degree 2
according to UL/EN 61010-1
Protection class according to
IEC/EN 60529
IP651), IP671)
if the following conditions are observed:
• The device must be wired.
• The cable glands must be tightened.
• The covers must be screwed tight.
• Unused cable glands must be sealed with the blind plugs provided.
The blind plugs are mounted upon delivery of the device.
•
Unused M12 connectors must be protected by a screwed plug.
Protection class according to
NEMA250
1)
4X if the following conditions are observed:
• The device must be wired.
• The cable glands must be tightened.
• The covers must be screwed tight.
• Unused cable glands must be sealed with the blind plugs provided.
The blind plugs are mounted upon delivery of the device.
•
Unused M12 connectors must be protected by a screwed plug.
1) not evaluated by UL; only IP64 is evaluated by the ATEX / IECEx notified/certification body
→
For the special operating conditions of devices with ATEX / IECEx certification, refer to the ATEX / IECEx
supplement for the device. The supplement is available at
English
Содержание Flowave 8098
Страница 1: ...Operating Instructions Type 8098 FLOWave L SAW Flowmeter Software version A 04 00 00 and higher...
Страница 4: ...General contents 4 Type 8098 FLOWave L English...
Страница 12: ...12 Type 8098 FLOWave L English...
Страница 36: ...36 Technical data Type 8098 FLOWave L English...
Страница 72: ...72 Type 8098 FLOWave L English...
Страница 78: ...78 Commissioning Type 8098 FLOWave L English...
Страница 96: ...96 Type 8098 FLOWave L English...
Страница 144: ...144 Type 8098 FLOWave L English...
Страница 248: ...248 Type 8098 FLOWave L English...
Страница 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Страница 304: ...304 Type 8098 FLOWave L English...
Страница 316: ...316 Type 8098 FLOWave L English...
Страница 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Страница 352: ...352 Appendix Type 8098 FLOWave L English...
Страница 353: ......
Страница 354: ...www burkert com...