1. Check that the distance to adjacent cabinets and worktop complies with the
drawing. (all brands at least 5 mm and for Neff at least 4 mm).
2. Remove heat protection cover strips with a distance < 5 mm.
5.4.4
Checking the ventilation between the oven and the hob
If the oven is being installed underneath a hob, the following must be considered:
•
the minimum distance
X
between the appliances
•
the minimum thickness
Y
of the worktop
Fig. 44:
Minimum distance and worktop thickness
Minimum distance
X
(mm)
Worktop thick-
ness
Y
(mm)
Full-surface induction hob
5
43
Induction hob
5
37
Gas hob
5
32
Electric hob
2
22
Table 12: Minimum distance and worktop thickness
1. Measure the minimum distance
X
between hob and oven.
2. Measure the minimum worktop thickness
Y
.