Test
2016-03-10 / DIS 184_58300000140186_ara_en_k
Copyright by BSH Hausgeräte GmbH
Page 64 of 181
5.4
Check the ventilation of the appliance in the
furniture
5.4.1
Checking the ventilation cut-out in the base unit
1. Check that the ventilation cut-out in the floor of the base unit complies with the
drawing.
2. If a ventilation cut-out too small, enlarge it (or have it enlarged) to comply with
the specification.
5.4.2
Checking the ventilation cut-out in the tall unit
1. Check that the ventilation cut-out in the floor of the tall unit complies with the
drawing.
2. If a ventilation cut-out too small, enlarge it (or have it enlarged) to comply with
the specification.
5.4.3
Checking the ventilation at the front
Cooling air from around the appliance’s housing is drawn in by the cooling fan and
blown out to the front between the fascia and the door.
Any vapours arising inside the appliance are taken up by this stream of air and also
blown out to the front.
For this reason, there must always be an air gap between the appliance and
adjacent cabinets or worktops.