6.18
Adjusting the fold-down door safety switch
Required tools:
?
2 distance gauges (magnets) [ 15000194] 2.0 mm
?
2 distance gauges (magnets) [ 15000194] 2.4 mm
?
VC850K digital multimeter [ 15000062]
?
Clamp-type test probe for multimeter, black, with tapper [ 00340951]
?
Clamp-type test probe for multimeter, red, with tapper [ 00340952]
?
SW3 hex key [ 00340819]
?
Torque spanner [ 15000085]
?
Torx-Bit TX20 [ 00340865]
Prerequisite:
•
Appliance is disconnected from the power supply.
•
Appliance has been removed. (Page 125)
•
Fold-down door is adjusted. (Page 131)
•
Upper section of the housing has been removed. (Page 121)
•
Back panel has been removed. (Page 122)
•
Right side panel has been removed. (Page 124)
•
Left side panel has been removed. (Page 123)
6.18.1
Adjusting the fold-down door safety switch (left)
1. Open the fold-down door.
2. Place the 2.4 mm distance gauges (cooking compartment flange flush at the
top / left and right).
3. Loosen two securing screws and the adjustment screw of the left safety switch.