Repairs
2016-03-10 / DIS 184_58300000140186_ara_en_k
Copyright by BSH Hausgeräte GmbH
Page 118 of 181
6.8
Flashing and coding
Valid for all brands.
The
iService interface
is located on the back of the control module.
In the IC6, the iService interface is a combination of a D-bus 2 interface and an HSI
interface.
EN:
H
igh
S
peed
I
nterface / DE: Hochgeschwindigkeitsschnittstelle
Fig. 55:
Example: iService interface at Siemens
1
HSI-D-Bus 2 interface
6.8.1
Flashing and coding the electronics
Fig. 56:
Overview of iService components
1
USB 3.0 HUB mains cable
6
UDA2
2
USB 3.0 HUB Micro-USB cable
7
D-Bus 2 cable
3
USB 3.0 HUB
8
USB isolator
4
USB cable to USB isolator
9
HSI cable
5
USB cable to UDA2
Required tools:
?
iService from version 1.36.3
?
USB cable [ 00341246]
?
UDA2 [ 00341244] from firmware 1.45
?
USB cable [ 00341246]
?
D-Bus 2 cable [ 00341245]
?
USB isolator [ 15000299]
?
HSI cable [ 15000300] from version 2215
?
USB 3.0 HUB [ 15000373]