Design and function
2016-03-10 / DIS 184_58300000140186_ara_en_k
Copyright by BSH Hausgeräte GmbH
Page 20 of 181
3.6
Double pump
The double pump consists of two pumps that are mounted on a carrier on a low-
vibration rubber bearing. The voltage supply is provided by a common connector
socket.
Depending on which pump is being operated, the water is pumped from the water
tank to the steam generator (filling) or from the steam generator to the water tank
(draining).
3.6.1
Double pump in appliances without microwave.
Fig. 19:
Position and connections for the pump
1
Connection to the tank
2
Connection to the steam generator
3.6.2
Double pump in appliances with microwave
Fig. 20:
Position and connections of the pump
1
Connection to the steam generator
2