4. Flame-Proving-When burner flame is proved at the flame-
proving sensor electrode FSE, the inducer motor IDM
switches to low-speed unless running at high-speed, and the
furnace control CPU begins the blower-ON delay period
and continues to hold the gas valve GV-M open. If the
burner flame is not proved within two seconds, the control
CPU will close the gas valve GV-M, and the control CPU
will repeat the ignition sequence for up to three more
Trials-For-Ignition before going to Ignition-Lockout. Lock-
out will be reset automatically after three hours, by
momentarily interrupting 115 vac power to the furnace, or
by interrupting 24 vac power at SEC1 or SEC2 to the
furnace control CPU (not at W/W1, G, R, etc.).
If flame is proved when flame should not be present, the
furnace control CPU will lock out of Gas-Heating mode and
operate the inducer motor IDM on high speed until flame is
no longer proved.
5. Blower-On Delay-If burner flame is proven the blower
motor BLWM is energized 66 sec after gas valve GV-M is
opened.
Low-heat-The blower motor BLWM is energized at LO
HEAT speed.
Hi-heat-The BLWM is energized at HI HEAT speed.
Simultaneously, the electronic air cleaner terminal EAC-1
is energized and remains energized as long as the blower
motor BLWM is energized.
TABLE 10—MODEL 352MAV ORIFICE SIZE AND HIGH/LOW-HEAT MANIFOLD PRESSURE FOR CORRECT INPUT (CONT.)
FOR USE WITH 060 THROUGH 120 SIZE FURNACES ONLY
(TABULATED DATA BASED ON 20,000/13,000 BTUH PER BURNER, DERATED 2 PERCENT FOR EACH 1000 FT ABOVE SEA
LEVEL)*
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
U.S.A.
and
Canada
4001
to
5000
9%
derate
725
43
3.7/1.5
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
42
3.4/1.4
750
44
3.4/1.4
43
3.5/1.5
43
3.7/1.5
43
3.8/1.6
42
3.2/1.4
775
44
3.7/1.6
44
3.8/1.6
43
3.4/1.4
43
3.5/1.5
43
3.7/1.5
800
44
3.51.5
44
3.6/1.5
44
3.7/1.6
44
3.8/1.6
43
3.4/1.4
825
44
3.2/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
44
3.7/1.6
850
45
3.5/1.5
45
3.8/1.6
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
875
45
3.3/1.4
45
3.6/1.5
45
3.7/1.6
44
3.2/1.3
44
3.3/1.4
900
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
45
3.8/1.6
925
47
3.7/1.6
45
3.2/1.4
45
3.3/1.4
45
3.4/1.5
45
3.6/1.5
950
47
3.5/1.5
47
3.6/1.5
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
U.S.A.
and
Canada
5001
to
6000
11%
derate
700
43
3.6/1.5
43
3.7/1.6
42
3.2/1.3
42
3.3/1.4
42
3.4/1.4
725
43
3.4/1.4
43
3.5/1.5
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
750
44
3.6/1.5
44
3.7/1.6
43
3.4/1.4
43
3.5/1.5
43
3.6/1.5
775
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
44
3.7/1.6
43
3.4/1.4
800
44
3.2/1.3
44
3.3/1.5
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
825
45
3.6/1.5
45
3.7/1.6
44
3.2/1.4
44
3.3/1.4
44
3.4/1.4
850
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
45
3.8/1.6
44
3.2/1.4
875
45
3.2/1.4
45
3.3/1.4
45
3.4/1.5
45
3.6/1.5
45
3.7/1.5
900
47
3.6/1.5
47
3.7/1.6
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
925
47
3.4/1.4
47
3.5/1.5
47
3.7/1.5
45
3.2/1.3
45
3.3/1.4
950
48
3.7/1.6
48
3.8/1.6
47
3.5/1.5
47
3.6/1.5
47
3.7/1.6
975
48
3.5/1.5
48
3.6/1.5
48
3.8/1.6
47
3.4/1.4
47
3.5/1.5
1000
48
3.3/1.4
48
3.5/1.5
48
3.6/1.5
48
3.7/1.6
48
3.8/1.6
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
U.S.A.
Only
6001
to
7000
13%
derate
650
42
3.2/1.3
42
3.3/1.4
42
3.4/1.4
42
3.5/1.5
42
3.6/1.6
675
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
700
44
3.8/1.6
43
3.4/1.5
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
725
44
3.6/1.5
44
3.7/1.6
44
3.8/1.6
43
3.4/1.4
43
3.5/1.5
750
44
3.3/1.4
44
3.4/1.5
44
3.6/1.5
44
3.7/1.6
44
3.8/1.6
775
45
3.8/1.6
44
3.2/1.4
44
3.3/1.4
44
3.4/1.5
44
3.5/1.5
800
45
3.5/1.5
45
3.7/1.5
45
3.8/1.6
44
3.2/1.4
44
3.3/1.4
825
45
3.3/1.4
45
3.4/1.5
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
850
47
3.7/1.6
45
3.2/1.4
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
875
47
3.5/1.5
47
3.6/1.5
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
* Orifice numbers shown in shading are factory installed.