Recommended Weekly Maintenance:
•
Clean and Adjust Trip Sensor System
•
Clean and Adjust Load Sensor System
•
Clean Control Panel Fan Filters
•
Check Belt Tracking
•
Check Bulb Status
Recommended Monthly Maintenance:
•
Check Camera Cooling Fan Filters
•
Clean Blinders
•
Clean Camera Lenses
•
Check Bulb Blinders Alignment
•
Check Camera Alignment
•
Clean Belt Movement Sensor
Clean and Adjust Trip Sensor System:
The trip sensor bridges are located at the front of
the heat chamber (Figure 1). The sensor
indicator lights on top of the bridges should be
on when no object is present on the belt. A strip
of reflective tape is located under the belt
directly underneath the trip sensor bridges, and
should be kept clean to properly reflect the light
emitted by the sensors. The bridges should be
positioned properly such that the sensors are
located directly over the reflective target.
TRIP BAR
TRIP INDICATOR LIGHT(S)
TRIP TARGET
LOAD
SENSOR LOAD TARGET
INDICATOR
LIGHT
Figure 1: Trip Sensor System
Clean and Adjust Load Sensor
System:
The load sensors are located at the front of the
belt (Figure 1). The sensor indicator lights on
top of the sensors should be on when no object
is present on the belt. A strip of reflective tape is
located under the belt, and should be kept clean
to properly reflect the light emitted by the
sensors. The sensors should be positioned
properly such that the sensors are pointed
directly at the reflective target.
Clean Control Panel Filters:
Each section control panel has metal cooling fan
filters located above the control panels (Figure
2). These filters should be kept as clean as
possible. The filters may be removed for easier
cleaning by unscrewing the nuts holding each in
place.