○ Pump: PMP1
○ Event: POWERON
○ Active: Yes
○ Change name to “POWER ON BLEED 1”
○ Repeat for the rest of the pumps
○ If you want to do this process manually every start-up or if you just refilled the
source tanks:
■ Click the Maintenance cards Icon (see User Manual page 46)
■ There are five tabs at the bottom of the card
● System
● Pretreat1
● Pretreat2
● Spray Head 1
● Spray Head 2
■ Click the Pretreat1 tab
● Press the “BLEED PRETREAT” button
■ Go to the Pretreat2 tab
● Press the “BLEED PRETREAT” button
■ Click Spray Head 1
● Press the “BLEED SPRAY PUMP” button
■ Click Spray Head 2
● Press the “BLEED SPRAY PUMP” button
● Reminder: ** the pumps need to be bled every time a source tank is refilled**
Shutdown Instructions
● Flush nozzles
○ There should be a Maintenance Task created to flush the nozzles (See page 48
of the User Manual for more information)
■ Go to the Maintenance screen
■ The system came with a task already created to flush the nozzles: under
“MAINTENANCE” on the right side of the screen: verify that there is a
green check mark next to “POWER DOWN FLUSH”
● Initiate Proper Shutdown (See page 39 of the User Manual for more information)
○ Click the home button
○ Press “POWER DOWN”
○ There will be a prompt for a Scheduled Event (the carriage flush)
○ Click yes
● Remove/Clean Nozzles
○ Remove all 6 nozzles from carriage
○ Take nozzles out of green/red Quick Connect Adapters
○ Soak nozzles in cleaning solution
Daily Instructions
Addendum: Synergy Maintenance Page 2