Synergy Software Page 12
• Spray Auto Start
: Enables Security for the Auto-
Start feature in the
Spray Screen
. While security is
enabled the operator will be prompted for password to
change the time of the Auto-Start. The operator will
still be able to press
Start
and
Pause
.
• Screen Locks
: These enable security for the various
screens as accessible from the
Home Navigation
Screen
. This includes the
Maintenance Screen
,
Diagnostic Screen
,
Calibration Screen
and
Settings
Screen
. When one of these is enabled, the operator
will be prompted for password every time they
attempt to access the given screen.
• Power Down
: Enables Security for the Power Down
button in the
Home Navigation Screen
. While
security is enabled the operator will be prompted for
password when attempting to initiate a power down
on the system.
Settings
The Settings screen is split into pages, and in these pages
the following settings can be found for the operator to
change as they wish. If a setting is NOT listed here it is
NOT ADVISED the Operator change it, doing so can cause
damage to the machine. The settings here are meant to
provide some customization.
• Load Returned Garment
: If checked, then when
the operator presses
Return
on the
Spray Screen
,
the garment returned will have its settings loaded to
replace what is currently displayed. In Queue Mode
this means the garment will be added to the top of the
queue.
• Rotate Queue On Start
: If checked, then when the
operator presses
Start
on the
Spray Screen
in
Queue
Mode
the garment will be removed from the queue
immediately. Otherwise, the system will wait until the
belt completes its next motion to remove the garment
from the queue.
• Spray Settings Format
: Determines what control will
be used for setting the Carriage Speed during a spray.
▪
Fixed Area Grams
: Grams setting will be
displayed (in grams), and it will provide a density
of the number entered divided by the number set
for
Fixed Area For Grams
. The system will
then use density calculations based on the Spray
Area and Nozzle Spray Densities to determine the
Carriage Speed
▪
Actual Grams
: Grams setting will be displayed (in
grams), and it will provide a density of the number
entered divided by the active
Spray Area
. The
system will then use density calculations based
on the Spray Area and Nozzle Spray Densities to
determine the Carriage Speed
▪
Density
: Density setting will be displayed (in
grams/in
2
). The system will then use density
calculations based on the Spray Area and Nozzle
Spray Densities to determine the Carriage Speed
▪
Speed
: Speed setting will be displayed (in in/s),
which will directly control how fast the carriage
moves during a spray.
• Fixed Area For Grams
: Determines the fixed area to
be used in
Fixed Area Grams
density calculations.
The default value is set for a 13” x 18” area (234 in
2
).
• Auto Start Mode
: Determines behavior of when the
auto-start countdown will begin after the last time the
start button has been effectively pressed.
▪
Start From Load
: Countdown will begin the
moment the belt has stopped and informs the
operator they can begin loading. This effectively
sets the timer to a Load Time.
▪
Start From Start
: Countdown will begin the
moment the start button has been effectively
pressed. This does not factor in timing delays such
as when the system will be able to start the belt
again.
▪
Start From Enabled
: Countdown will begin the
moment the start button is enabled.
• Display Countdown
: If checked then the countdown
will be displayed in the start button. Otherwise,
the start button value will remain static and the
countdown will only be visible on the load zone.
• Image Halo Top/Bottom
: Affects
Queue Mode
.
When a garment is scanned into the system, the value
set will be added to the top and bottom of the Spray
Zone indicated by the scan (ie, if the scanned image
has a height of 8” and the value is 0.5”, the Spray
Area will be 9” tall).
• Image Halo Left/Right
: Affects Queue Mode. When
a garment is scanned into the system, the value set
will be added to the left and right of the Spray Zone
indicated by the scan (ie, if the scanned image has a
width of 8” and the value is 0.5”, the Spray Area will
be 9” wide).
• Temperature Unit
: The temperature unit to display
for the Cure Temp. Available in Fahrenheit and
Celsius.
• Spray Before Bleed
: If checked then the system will
decompress spray pump lines before attempting a
bleed. This can be useful if bleeds are stopping early
due to mixing tanks approaching overflow. This
setting means
Bleed Spray Pump
will waste a small
amount of fluid.
• Carriage Flush Time
: The amount of time that an
Automated Maintenance Task
will spend flushing