■ Perform a
bleed
on
Pretreat1
to pull air in and push any remaining
pretreat back into the tank
● Maintenance Card→ Pretreat1 tab on the bottom of the page
● Click Bleed Pretreat
■ Perform a
bleed
on
Pretreat2
to pull air in and push any remaining
pretreat back into the tank
● Maintenance Card → Pretreat2 tab on the bottom of the page
● Click Bleed Pretreat
■ Connect the Water Source cap to the jug that has the cleaning solution
■ Perform a
Fill Line With Water
for the
Pretreat1
line
● Maintenance Card → Pretreat1 tab on the bottom of the page
● Click Fill Line with water
■ Perform a
Fill Line With Water
for the
Pretreat2
line
● Maintenance Card → Pretreat2 tab on the bottom of the page
● Click Fill Line with water
■ Let cleaning solution sit for
at least 15 minutes
■
Replace the cleaning solution jug
with the Water Source jug
■ Perform a
Fill Line with Water
for
Pretreat1
■ Perform a
Fill Line with Water
for
Pretreat2
■ Place the source tubes for Pretreat1 and Pretreat2 back into the tanks
■ Perform a
Fill Line with Pretreat
for
Pretreat1
● Maintenance Card → Pretreat1 tab on the bottom of the page
● Click Fill Line with Pretreat
■ Perform a
Fill Line with Pretreat
for
Pretreat 2
● Maintenance Card → Pretreat2 tab on the bottom of the page
● Click Fill Line with Pretreat
Bimonthly Instructions
● How to clean pretreater/transfer belt:
○ Pull out one of the white zipper rods in between the grey pieces on the belt using
a pair of needlenose pliers
○ Remove the belt from the machine
○ Use cleaning solution to scrub off built up pretreat
○ Hose down with water
○ Let dry
● While the belts are off:
○ Clean the axle with cleaning solution, but be careful
NOT to shift any of the
teeth
used to drive the belt!
○ Wipe down the area underneath the belts
● To replace the belt
○ The easiest way is when the Synergy Software is not running
○ Run the belt around both axles and line up the teeth to the wider slots on the belt
(belt orientation doesn’t matter)
Addendum: Synergy Maintenance Page 4