9.2 Maintenance
Clean the heat exchanger and the ventilator once every 3 years.
1. Disconnect power from appliance (zie
op pagina 32).
2. Loosen the two screws between the protective cover and the filter door.
3. Slide the protective cover to the side and remove it from the appliance.
4. Remove the front covers.
5. Disconnect the ventilator cables from the circuit board.
6. Remove the circuit board holder.
7. Remove the soundproofing blocks.
8. Remove the ventilator unit.
9. Ensure that the balance weights in the system ventilator have not moved!
10. Clean the vanes of the ventilator with a dry brush.
11. Carefully clean the heat exchanger with a vacuum cleaner.
12. Check the heat exchanger for any leaks.
13. Mount the ventilator unit.
14. Mount the soundproofing blocks.
15. Mount the circuit board holder.
16. Mount the ventilator cable onto the circuit board.
17. Mount the front covers and the protective cover.
18. Switch the appliance on (zie
19. Press
[R]
on the control panel for 5 seconds to remove the filter indication.
The notification message FILTER flashes briefly.
The appliance is in operating mode.
The standard maintenance period is 3 years. The required maintenance period depends on the circumstances.