5 Installation
5.1 Installation general
The appliance is delivered ready to be plugged in. When placing the appliance, the water connections and the
system air ducts have to be installed on the discharge side. Afterwards, the appliance can be connected to the
electricity network.
The installation of the Air Comfort must meet the following regulations:
▪
NEN 3028: Safety regulations for central heating installations
▪
NEN 1087: Regulations for the ventilation of homes and residential buildings
▪
NEN 1010: Safety regulations for low-voltage installations.
▪
NEN 3287: Regulations for connecting indoor plumbing in homes and residential buildings.
▪
ISO 61: Quality requirements of ventilation systems in homes.
▪
Relevant articles in accordance with the Building Decree.
▪
Any additional regulations of the local utility companies.
▪
Installation of the Air Comfort.
Install the Air Comfort:
1. Place the appliance (zie
2. Install the water connections (zie
op pagina 23).
3. Install the air ducts (zie
op pagina 24).
4. Connect the electrical connections (zie
5.2 Placing the appliance
When placing the Air Comfort take into account the following environmental factors:
▪
The room where the appliance is installed must be frost-free.
▪
The room where the appliance is set up must provide enough space for service. There must be at least 1 m of
free space at the front and a free standing height of 1.8 m.
▪
If applicable, there must be a good condensation discharge with water trap and slope for condensed water in
the room where the appliance is set up, or if not this must be possible to set up.
▪
When using free air intake, the room in which the appliance is set up has to be in open connection with the
rest of the building.
Place the Air Comfort loosely on the floor:
▪
Ensure that the sides and top of the appliance have at least 120 mm of free space from the walls and ceiling.
▪
Place the appliance on an assembly table if the floor is wet, uneven or if cooling is used.
▪
Place the appliance as closely as possible to the water supply and discharge.
▪
Place the appliance as centrally as possible in relation to the air ducts.
▪
Ensure that the appliance is set up so that it is even and does not vibrate.