![Brink Air Comfort Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/brink/air-comfort/air-comfort_installation-regulations_2812493025.webp)
1. Make the required opening in the air distributing box.
2. Connect the warm air duct on to the desired output of the air distributing box.
3. When mounting flexible ducts, bear in mind that it must be possible to replace them in due course.
Ensure that the ducts do not form a straight connection between 2 rooms, so that cross-talk interference does not arise.
5.5 Electrical connections
The Air Comfort must be connected to the electricity network with the mains plug.
See section Electrical connection accessories
Connecting external connectors Air Comfort
connecting the extra options.
5.5.1 Connecting the mains plug
The cable of the 230 V mains plug is attached behind the protective cover. In the protective cover there are
openings (1) through which you can feed the cable.
q
Ensure that the power cable is always free from the heat exchanger.
The electrical installation must meet the requirements of your electricity firm and the NEN 1010 safety
regulations for low-voltage installations.
Warning!
When carrying out work on the appliance, always disconnect the power by pulling the
mains plug from the power socket. The ventilator and circuit board work under high
voltage.
Connect the mains plug:
1. Feed the cable of the plug through the opening.
2. Connect the mains plug to an earthed wall socket.
5.5.2 Connecting the cooling
Connect the cooling:
1. Loosen the two screws between the protective cover and the filter door.
2. Slide the protective cover to the side and remove it from the appliance.
3. Connect the cooling relay to ports 7 and 8 of the 9-pin connector, see (1) in section Connector connections (zie
Connecting external connectors Air Comfort
4. Connect the frost protection relay to ports 5 and 6 of the 9-pin connector.
5. Connect the switch contact to ports 1 and 2 of the 9-pin connector.
Air Comfort 614788-B
Brink / 25
Содержание Air Comfort
Страница 1: ...Air Comfort English Installation regulations ...
Страница 2: ......
Страница 13: ...Water connections left hand version Air Comfort Air Comfort 614788 B Brink 13 ...
Страница 50: ...614788 B ...