9
8
This product contains batteries and recyclable electronic waste. To protect the environment,
do not dispose of it in the household waste, but take it to appropriate local collection points.
1
Herzog L, Phillips SG. Addressing concerns about fever. Clin Pediatr (Phila) 2011 May;50(5):383-90.
2
Sund-Levander M, Forsberg C, Wahren LK. Normal oral, rectal, tympanic and axillary body
temperature in adult men and women: a systematic literature review. Scand J Caring Sci 2002
June;16(2):122-8.
Guidance and manufacturer’s declaration – electromagnetic emissions
The PRT2000 equipment is intended for use in the electromagnetic environment specifi ed
below.
The customer or the user of the PRT2000 should assure that it is used in such an environment.
Emissions Test
Compliance
Electromagnetic environment – guidance
RF Emissions
CISPR 11
Group 1
The ME equipment uses RF energy only for its
internal function. Therefore, its RF emissions are
very low and are not likely to cause any interfer-
ence in nearby electronic equipment.
RF Emissions
CISPR 11
Class B
Complies
Harmonic emissions
IEC 61000-3-2
Not Applicable
The ME equipment is
solely battery powered.
Voltage fl uctuations /
fl icker emissions
Not Applicable
Non-Life Support Equipment Separation Distance Calculation
(3Vrms / 3V/m compliance)
Rated maximum
output power of
transmitter (W)
Separation distance according to frequency of transmitter (m)
150 kHz to 80 MHz
in ISM bands
d
= [
3.5
]
P
V
1
80 MHz to 800 MHz
d
= [
3.5
]
P
E
1
800 MHz to 2.5 GHz
d
= [
7
]
P
E
1
0.01
/
0.12
0.23
0.1
/
0.38
0.73
1
/
1.2
2.3
10
/
3.8
7.3
100
/
12
23
Guidance and manufacturer’s declaration – electromagnetic immunity
The PRT2000 is intended for use in the electromagnetic environment specifi ed below.
The customer or the user of the PRT2000 should assure that it is used in such an environment.
Immunity test
IEC 60601 test
level
Compliance
level
Electromagnetic environ-
ment – guidance
Electrostatic dis-
charge (ESD)
IEC 61000-4-2
±6kV Contact
±8kV Air
Complies
Floors should be wood,
concrete, or ceramic tile.
If fl oors are covered with
synthetic material, the
relative humidity should be
at least 30%.
Radiated RF
IEC 61000-4-3
3 V/m 80MHz to
2.5GHz
Complies
Field strengths outside
the shielded location
from fi xed RF transmitters,
as determined by an
electromagnetic site survey,
should be less than 3 V/m.
Interference may occur in
the vicinity of equipment
marked with the following
symbol:
Separation distance
calculation provided above.
If a known transmitter is
present the specifi c distance
can be calculated using the
equations.
Conducted RF
IEC 61000-4-6
3Vrms 150kHz to
80MHz
Not Applicable
(no electrical
cabling)
Electrical fast
transient
IEC 61000-4-4
±2kV power line
±1kV I/O lines
Not Applicable
The ME equipment
is solely battery powered.
Surge
IEC 61000-4-5
±1kV
diff erential
±2kV common
Not Applicable
Power frequency
magnetic fi eld
IEC 61000-4-8
3 A/m
Complies
Power frequency
magnetic fi elds should be at
levels characteristic of a
typical location in a typical
commercial or hospital
environment.
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
>95% dip 0.5 cycle
60% dip 5 cycles
70% dip 25 cycles
95% dip 5 sec.
Not Applicable
The ME equipment
is solely battery
powered.