AUTODOME IP starlight 7000 HD
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en
27
Bosch Security Systems
Operation Manual
2016-07 | 1.0 | F.01U.283.679
Fuse Specifications
Volts
XF101 Mains
XF102 Camera XF103 Heater
24 V
T 5.0 A
T 2.0 A
T 3.15 A
115 V
T 1.6 A
T 2.0 A
T 3.15 A
230 V
T 0.8A
T 2.0 A
T 3.15 A
!
Warning!
Fuse replacement by qualified service personnel only. Replace with same type fuse.
Fuse Specifications
Volts
XF101 Mains
XF102 Camera XF103 Heater
24 V
T 5.0 A
T 2.0 A
T 3.15 A
115 V
T 1.6 A
T 2.0 A
T 3.15 A
230 V
T 0.8A
T 2.0 A
T 3.15 A
The following table lists the Power Supply Box connectors:
No.
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Ground
Grounding Screw
P101
115/230 VAC or
24 VAC Power In
Line
NC
Neutral
P106
SERIAL
COMMUNICATIONS
CODE-
(Audio IN-,
Audio in
signal
ground)
CODE+
(Audio IN+)
Earth GND
(Ground)
(Audio)
RXD
(Audio OUT+)
TXD
(Audio OUT-;
Audio out
signal
ground)
Signal
GND
(Ground)
P107
24 VAC Power
(Arm Harness)
Camera
24 VAC
Camera
24 VAC
Earth
Ground
Heater
(24 VAC)
Heater
(24 VAC)
Table 7.1: Power Supply Box Connections
Notice!
Pins for P106 1, 2, 4, and 5 are used for audio input and output for AUTODOME 7000 Series
cameras; however, their labels are still those of previous versions of analog AUTODOME
cameras.
!
Warning!
For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting to
the unit must be routed separately inside different permanently earthed metal conduits (not
supplied).