74
en | Connection
AUTODOME IP starlight 7000 HD
2016-07 | 1.0 | F.01U.283.679
Operation Manual
Bosch Security Systems
Maximum Wire Distances from Power Supply to AUTODOME
24 V to AUTODOME
VA / Watts
14 AWG
(2.5 mm)
16 AWG
(1.5 mm)
18 AWG
(1.0 mm)
HD models with IVA, Outdoor
60 / 55
58 m (190 ft)
36 m (119 ft)
23 m (75 ft)
Maximum Wire Distances from Power Supply to AUTODOME 7000 HD
24 V to AUTODOME
7000
VA / Watts
14 AWG
(2.5 mm)
16 AWG
(1.5 mm)
18 AWG
(1.0 mm)
HD models with IVA, Indoor
35 / 19
99 m (325 ft)
62 m (205 ft)
39 m (129 ft)
HD models with IVA, Outdoor
60 / 55
58 m (190 ft)
36 m (119 ft)
23 m (75 ft)
15.3
Ethernet Connections
The camera connects to a 10 Base-T/100 Base-TX network either directly or via a hub. Video,
optional audio input, optional audio output, and control are transmitted over a standard TCP/
IP network using the built-in Web server. In addition, power can be supplied over the Ethernet
cable using the Bosch High PoE 60W midspan (sold separately). Power can also be supplied
over the Ethernet cable to in-ceiling models and indoor/outdoor pendant models used in
indoor applications (where the heater is not powered) using PoE+ PSEs (midspan switches)
compliant with the IEEE 802.3at, class 4 standard.
The camera can be connected simultaneously to a 24 VAC power supply and to a High PoE 60
W midspan. The camera uses power from the 24 VAC power supply. If this power supply fails,
the camera seamlessly switches power input to the High PoE 60 W midspan. The camera
switches back to the 24 VAC power supply once power is restored.
Refer to Using the IP Interface, for instructions on configuring an IP environment.
!
Warning!
BOSCH High PoE or PoE+ (802.3at)
: Use only approved High PoE or PoE+ (802.3at) devices.
For outdoor pendant applications that require heater power use only the Bosch High PoE
midspan (sold separately) to power the camera and the heaters. For in-ceiling or indoor
pendant applications that don't require heater power, standard PoE+ (802.3at) midspans or
switches can be used to power the camera.
When powering the camera via PoE or a midspan device, additional surge protection is
required.
If auxiliary power (24VAC camera and 24VAC heater) and High PoE are applied
simultaneously, the camera selects the auxiliary 24VAC input and draws minimal power from
the High PoE midspan.
!
Caution!
Ethernet CAT 5E/CAT 6 cables must be routed through earth-grounded conduit for indoor or
outdoor applications. For outdoor applications, the conduit should be capable of
withstanding the outdoor environment.