68
en | Central Console, computer setup and programming
Security Escort
2018.03 | SE3v1.0 | DOC
Technical Reference Manual
Robert Bosch (SEA) Pte Ltd
The elements of the
Edit Transponder
’
s Database Record
dialog are described as follows:
Element
Usage/Description
Type
Select the type of transponder record from the drop-down list box.
There are two types of transponders, namely: "transponder" and "SE
coordinator". Default is "SE coordinator".
Name
Key in the name of the SE coordinator.
ID
Key in the number that is assigned to the SE coordinator at system
set-up. This is the Radio ID found on the product label of the SE
coordinator circuit board. This
ID
is used by the Central Console to
identify the SE coordinator during all communications between the
Central Console and the SE coordinator.
Comm Mode
This field is disabled and defaulted as "TCP IP" if the
Type
selected is
"SE coordinator". "TCP IP" is the only communication mode between
the Central Console and the SE coordinator.
IP Address/Host
Name
Key in the IP address or Host Name of the SE coordinator.
Port No.
Key in the communications port that is used by the Central Console
to communicate with the SE coordinator. Valid port is between "1"
and "65535".
Isolate From All
Other Transponders
For Location
Select this checkbox if this SE coordinator is isolated from all other
SE coordinators for location considerations. This should be used
when distant SE coordinators sometimes hear an alarm and throw off
the alarm location calculation. If this checkbox is selected, it
indicates that this SE coordinator is protecting an area that is
independent of all other SE coordinators in the system.
When an alarm is reported, and the SE receivers on this SE
coordinator have the best reception, only the SE receivers on this SE
coordinator will be considered for the location of this alarm. If
another SE coordinator has the best reception, then the SE receivers
on this SE coordinator will be ignored for the location of this alarm.
Ignore
Communications
Failure
Select this checkbox if communication failures is to be ignored for
this SE coordinator. It is used during a new installation of SE
coordinators that are not yet fully on line. During system
maintenance, when an SE coordinator is out of service for a while, it
is used so that the communication failure messages will not flash on
the screen and distract the operator.
Selecting this checkbox causes
the system to ignore communication failure. Therefore, if
communication fails with this SE coordinator, the area that this SE
coordinator protects will not be protected, and alarms from
subscribers in that area will be missed without the operator
’
s
knowledge. This checkbox should not be selected in a live system.
Trouble Type Text
This is the text that will be shown in the trouble dialog when the
Remote Key input on the SE coordinator goes active (shorted).