For all SE receivers except the last SE receiver, locate the jumper block J5 and set the
jumper over the jumper pins 2 and 3.
Testing SE receiver spacing
The spacing mode can be used to verify the maximum acceptable spacing of SE receivers.
Enable or disable the spacing mode by setting switch number 1 on dip switch CFG2. Spacing
mode is disabled by default, where switch number 1 is set to the OFF position. To enable the
spacing mode, set switch number 1 on dip switch CFG2 to the ON position.
Enable/disable Spacing Mode
Switch Number on Dip Switch CFG2
1
Disable Spacing Mode
(default setting)
OFF
Enable Spacing Mode
ON
Tab.
5.4:
Enable or disable the spacing mode on dip switch CFG2
To test the spacing of SE receivers:
1.
Mount the first SE receiver (SE receiver 1). Set switch number 1 on dip switch CFG2 to
the ON position. Power the SE receiver from a 24 VDC source.
2.
Take the second SE receiver (SE receiver 2) and an SE transmitter a distance away from
the first SE receiver.
3.
Activate the SE transmitter.
4.
If SE receiver 1 sounds the test beep, SE receiver 2 is within range. Repeat this test until
SE receiver 1 no longer sounds the test beeps. Move back to the last location where SE
receiver 1 received the test beeps. This location marks the maximum spacing between
the SE receivers. The distance between the SE receivers should not exceed 25 m (80 ft.)
indoors and 90 m (300 ft.) outdoors. Mount SE receiver 2 at this location or closer to SE
receiver 1.