Security Escort
Configuring equipment using Utility tool | en
83
Robert Bosch (SEA) Pte Ltd
Technical Reference Manual
2018.03 | SE3v1.0 | DOC
Element
Usage/Description
MAC Address
MAC address of the SE coordinator. This information cannot be
changed by the user.
Version
Firmware version of the SE coordinator.
Serial Number
Serial number of the SE coordinator.
Description
Description of the SE coordinator. Maximum length is 20 characters.
IP Address
IP address of the SE coordinator. A factory configured SE coordinator
has the default IP address of 192.168.1.100. Valid IP addresses are
from 1.0.0.0 to 255.255.255.255.
Subnet Mask
Subnet mask of the SE coordinator. A factory configured SE
coordinator has the default subnet mask of 255.255.0.0. Valid subnet
masks are from 1.0.0.0 to 255.255.255.255.
Gateway
Gateway of the SE coordinator. A factory configured SE coordinator
has the default gateway of 192.168.1.1. Valid gateways are from
1.0.0.0 to 255.255.255.255.
Port
TCP/IP port of the SE coordinator. A factory configured SE
coordinator has the default port of 20000. Valid ports are from 00001
to 65536.
Receivers
Click the
[Scan]
button to scan the SE receivers of the SE
coordinator.
Transmitters
Click the
[Scan]
button to scan the SE transmitters of the SE
coordinator.
[Save] / [Edit]
Click the
[Edit]
button to change the information of the SE
coordinator. The
[Edit]
button changes to
[Save]
button. After making
the necessary changes, click the
[Save]
button to affect the changes.
The
[Save]
button changes to
[Edit]
button.
Status
Status of the SE coordinator. “OK” is displayed when communication
between the
Utility tool
and SE coordinator is fine. “FAIL” is
displayed if there are communication issues.
8.1.2
Modifying SE coordinator network settings
Follow the instructions below to change the network information of the SE coordinator. You
can only change the data of one SE coordinator at any one time.
1.
Click the
[Edit]
button under the
Save/Edit
column for the SE coordinator row entry that
you wish to change. The
[Edit]
button changes to the
[Save]
button. Click once on the
data that you wish to change. The field becomes enabled for data entry.