en | Troubleshooting coordinators, points and receivers
Security Escort
2018.03 | SE3v1.0 | DOC
Technical Reference Manual
Robert Bosch (SEA) Pte Ltd
9.7.3
View Alarm Groups
Select a schedule where you wish to view the associated alarm groups, and click the
[View
Alarm Groups]
button. The list of alarm groups that are assigned to the selected schedule,
and their current arming state are shown.
Figure
9.15: View Alarm Groups dialog
The “ON” and “OFF”
Group State
indicates that the alarm group is under manual control.
“AUTO” indicates that the alarm group is under control of the selected schedule. This alarm
group will be armed automatically once the schedule becomes active.
9.7.4
Alarm Groups
This dialog allows setup and arm/disarm control of the 99 alarm groups. Any number of point
type transmitters can be assigned to an alarm group in the
Subscriber Database
’
s Advanced
dialog. However, each transmitter can only be assigned to one alarm group.
Figure
9.16: Alarm Groups dialog