![Bosch SE3000 Series Скачать руководство пользователя страница 190](http://html.mh-extra.com/html/bosch/se3000-series/se3000-series_technical-reference-manual_44853190.webp)
190
en | System menus and dialogs
Security Escort
2018.03 | SE3v1.0 | DOC
Technical Reference Manual
Robert Bosch (SEA) Pte Ltd
Element
Usage/Description
[Tamper Map]
Requests a map of all the points that are currently reporting a
tamper condition to the system. The
[Tamper Map]
button displays
a map with “1” in the locations corresponding to points that are
reporting tamper. A “0” (zero) indicates points that are not
tampered.
[Output 1]
Requests a map of all the
Output 1
of SE receivers that are turned
on for this SE coordinator. The
[Output 1]
button displays a map
with “1” in the locations corresponding to points that are turned
on.
[Output 2]
Requests a map of all the
Output 2
of SE receivers that are turned
on for this SE coordinator. The
[Output 2]
button displays a map
with “1” in the locations corresponding to points that are turned
on.
[Horn
-
Siren Map]
Requests a map of all the points that have their horn or sirens on,
on this SE coordinator. The
[Horn
-
Sirens Map]
button displays a
map with “1” in the locations corresponding to points which have
their outputs on. A “0” (zero) indicates that the output is off.
[Green LED Map]
Requests a map of all the points on this SE coordinator that have
their spare outputs - green LED on. The
[Green LED Map]
button
displays a map with “1” in the locations corresponding to points
which have their outputs on. A “0” (zero) indicates that the output
is off.
[Strobe
-
Red LED
Map]
Requests a map of all the points on this SE coordinator that have
their strobe - red LED on. The
[Strobe - Red LED Map]
button
displays a map with “1” in the locations corresponding to points
which have their outputs on. A “0” (zero) indicates that the output
is off.
[Input 1]
Requests a map of all the
Input 1
of SE receivers that are currently
monitored for the SE coordinator. The
[Input 1]
button displays a
map with “1” in the locations corresponding to inputs that are
triggered.
[Input 2]
Requests a map of all the
Input 2
of SE receivers that are currently
monitored for the SE coordinator. The
[Input 2]
button displays a
map with “1” in the locations corresponding to inputs that are
triggered.
[Out Of Service Map]
The
Out Of Service Map
shows those SE receivers that are
currently out of service. Se receivers may be taken out of service
and returned to service by selecting the point using
MUX Bus
Point
dialog in the bottom right corner of the screen and clicking
the
[Point Out Of Service]
or
[Point In Service]
button. Points can
be selected by typing in the point number or by using the
[+]
and
[-]
buttons, or the
[?]
button.
Others
Содержание SE3000 Series
Страница 1: ...Security Escort SE3000 Series en Technical Reference Manual ...
Страница 2: ......
Страница 255: ......