72
en | Central Console, computer setup and programming
Security Escort
2018.03 | SE3v1.0 | DOC
Technical Reference Manual
Robert Bosch (SEA) Pte Ltd
Figure
7.7: Data entry after selecting "SE receiver" as Point Type
If any SE receivers (including the SE coordinator, which is also SE receiver 0) is using the APS-
PSU-60 power supply, select the
Use PSU60
checkbox. The power supply operation requires
periodic and frequent auto switching from its battery to the direct current, and back.
The
Popup trouble filter
feature allows you to select the type of troubles (for example
AC
loss / Input 1
) that is reported as a popup dialog. Normally, we will configure the system to
monitor these troubles as they are important and may affect the entire operation.
Therefore, due to results of these internal APS-PSU-60 checks, the Central Console software
may inadvertently report
AC loss / Input 1
trouble as popup trouble dialog windows. The
frequency of these windows will cause unnecessary disruption to the normal SE operation.
Turning on the
Use PSU60
option will force the Central Console software to verify that actual
AC loss / Input 1
trouble was triggered before it displays the popup trouble dialog window.
Ensure that you select the
Use PSU60
checkbox if the SE receiver (0 to 15) is using the APS-
PSU-60 power supply.
SE receiver has two analog inputs with four state supervised monitoring. Click the
[Inputs]
button to configure the input mapping of the device.
Input 1
and
Input 2
can be configured
with their four states, namely
Short
,
Off
,
On
or
Broken
. Click the
[Save]
button to save the
changes or
[Cancel]
button to abort the changes.
Figure
7.8: SE receiver Inputs dialog