![Bosch SE3000 Series Скачать руководство пользователя страница 147](http://html.mh-extra.com/html/bosch/se3000-series/se3000-series_technical-reference-manual_44853147.webp)
Security Escort
Troubleshooting coordinators, points and receivers | en
147
Robert Bosch (SEA) Pte Ltd
Technical Reference Manual
2018.03 | SE3v1.0 | DOC
<ProtectedAreaPoints ProtectedXArea1="386"
ProtectedYArea1="292" ProtectedXArea2="386" ProtectedYArea2="292"
ProtectedXArea3="385" ProtectedYArea3="209" ProtectedXArea4="470"
ProtectedYArea4="209" ProtectedXArea5="468" ProtectedYArea5="297"
ProtectedXArea6="387" ProtectedYArea6="294" />
</Area>
<Area AreaID="1" FloorIcon="9" PagerGroupA="0" BitmapNumber="0"
LocationText="1st Floor Main Entrance & Accounting Area"
MatrixSwitchText="">
<ProtectedAreaPoints ProtectedXArea1="385"
ProtectedYArea1="293" ProtectedXArea2="385" ProtectedYArea2="293"
ProtectedXArea3="468" ProtectedYArea3="297" ProtectedXArea4="470"
ProtectedYArea4="351" ProtectedXArea5="384" ProtectedYArea5="348"
ProtectedXArea6="386" ProtectedYArea6="294" />
</Area>
</Areas>
</Transponder>
<Transponder TransponderID="1" Name="South Point Hospital"
IsIPConnected="0" IPAddress="" PortNumber="0" CommPortIndex="0">
<Receivers>
<Receiver Address="6" PointType="0" AlgoNumber="0" AlarmIcon="9"
Rx_LocationText="1st Floor by South Exit Door" MapXPosition="430"
MapYPosition="479" SensitivityAdjust="0" BitmapNumber="0" />
<Receiver Address="7" PointType="0" AlgoNumber="0" AlarmIcon="9"
Rx_LocationText="1st Floor Center of Main Lobby" MapXPosition="429"
MapYPosition="215" SensitivityAdjust="0" BitmapNumber="0" />
</Receivers>
</Transponder>
The following attributes are applicable to the respective elements.
<Transponder> element
Attribute
Value
TransponderID
ID of SE coordinator record, 1-255. This field should contain only
numeric ASCII characters.
iCoordinatorID
Radio ID of the SE coordinator. 0 (default for transponders),
1-9999999 (SE coordinator). This field should contain only
numeric ASCII characters.
Name
Name of the SE coordinator. This field may be up to 24
characters. This field may contain any printable ASCII character
except the ‘?’
IsIPConnected
0 if transponder is connected via RS232, 1 if transponder is
connected via TCP IP. This field should contain only numeric
ASCII characters.
IsCoordinator
0 if it is a transponder, 1 if it is an SE coordinator. This field
should contain only numeric ASCII characters.