System menus and dialogs | en
181
Robert Bosch (SEA) Pte Ltd
Technical Reference Manual
2018.03 | SE3v1.0 | DOC
Element
Usage/Description
Select destination group
History screen
This option selects the events to be displayed on the computer
screen when
Show history
is selected.
Printer
This option selects the events to be sent to the printer.
History archive file A
This option selects the events to be sent to the “a_audit.txt” file
stored in the Security Escort sub-directory (typically “C:
\ESCORT”). There is a minimum set of events that cannot be
disabled, so they are always recorded.
History archive file B
This option selects the events to be sent to the “b_audit.txt” file
stored in the Security Escort sub-directory (typically “C:
\ESCORT”).
System serial port 1
This option selects the events to be sent to the system serial port
1. System serial port 1 is assigned a physical comm port in the
Remote Comm Port Setup
dialog, and the
History Filter Output
field must be set in the
Remote Setup
dialog.
System serial port 2
This option selects the events to be sent to the system serial port
2. System serial port 2 is assigned a physical comm port in the
Remote Comm Port Setup
dialog, and the
History Filter Output
field must be set in the
Remote Setup
dialog.
Transponder restriction group
No restriction
This selection is typically left at this setting at all times. The output
is not restricted by an individual SE coordinator.
Only from transponder
selected
The selected events are only output if they were reported from the
SE coordinator selected in the drop-down list box above.
All from transponder
selected
All events are reported from the SE coordinator selected above.
The selected events are reported from all other SE coordinators in
the system.
Check to output the event group
Alarms
Outputs the information about an alarm including location, but not
the SE coordinator and SE receiver levels. This is the data typically
sent to a printer.
Points, reporting alarm
Outputs the SE coordinator and SE receiver levels for an alarm.
Typically, this is the data too detailed to send to a printer and is
used for diagnostics, not normal system operation.
Tests, single line
Outputs the simple information about a test. Typically, this is the
data normally sent to a printer.
Tests including point
Info
Outputs the SE coordinator and SE receiver levels for a test. This is
the data usually too detailed to send to a printer and is used for
diagnostics, not normal system operation. If this option is selected,
Test, single line
option would not be selected for the same output
device.