Usage/Description
Monitored periods
This is the number of supervision intervals that are consecutively
missed before notification is generated for a specific transmitter
that stopped reporting supervision transmissions. Default is 8.
MUX point / SE receiver troubles
group
AC loss / Input 1
The SE receiver tested the presence of Input 1 and the test failed.
For information on AC loss, please refer to the Security Escort
manuals.
Low Battery / Input 2
The SE receiver tested for presence of Input 2 and the test failed.
For information on Low Battery, please refer to Security Escort
manuals.
Tamper (no delay)
Whenever the cover is removed from an SE receiver, the on-board
microprocessor detects the tamper and it is reported without delay
to the SE coordinator.
No response
Whenever an SE receiver fails to respond to a command from the
SE coordinator, a “No Response” message is sent by the SE
coordinator to the Central Console. This can occur if a bus wire is
cut or a device is damaged.
Jamming
Each SE receiver monitors the level of radio energy being received
at all times. If the level exceeds a preset threshold, for a preset
length of time, the on-board microprocessor reports jamming.
Bad checksum
This message is generated by the SE coordinator and sent to the
Central Console whenever the SE coordinator detects message
errors in the communications between SE receivers.
MUX point troubles
group
Output device error
The SE coordinator generates this message when it commands an
SE receiver to activate or deactivate an output device (siren,
strobe, horn, or LED) and the device fails to respond correctly.
Others
COMM port overload
The notification is generated if the communications traffic to the
SE coordinator exceeds the system is capability.
Network comm failure
The notification is generated if the communication between the
master and slave computers fails.
All troubles to history
Saves all troubles to history file.
Pop-up trouble and
pager delay
The delay in seconds before a trouble displays on the computer
screen or pager message is dispatched. If a restore for a trouble is
received before a trouble is displayed (this delay expires), the
trouble and the restore are ignored. Tamper troubles are not
delayed. Default is 30 seconds.
[Save]