E2600 DSA E-Series iSCSI Disk Arrays
Turning on the Power and Checking for Problems | en
83
Bosch Security Systems
Installation Manual
- | V2 | 2012.09
AA
The ESM A firmware is in the process of booting (the diagnostic
indicator is not yet set).
bb
The ESM B firmware is in the process of booting (the diagnostic
indicator is not yet set).
L0
The controller types are mismatched, which result in a suspended
controller state.
L2
A persistent memory error has occurred, which results in a
suspended controller state.
L3
A persistent hardware error has occurred, which results in a
suspended controller state.
L4
A persistent data protection error has occurred, which results in a
suspended controller state.
L5
An auto-code synchronization (ACS) failure has been detected,
which results in a suspended controller state.
L6
An unsupported host interface card has been detected, which
results in a suspended controller state.
L7
A sub-model identifier either has not been set or has been
mismatched, which results in a suspended controller state.
L8
A memory configuration error has occurred, which results in a
suspended controller state.
L9
A link speed mismatch condition has been detected in either the
ESM or the power supply, which results in a suspended controller
state.
Lb
A host interface card configuration error has been detected, which
results in a suspended controller state.
LC
A persistent cache backup configuration error has been detected,
which results in a suspended controller state.
Ld
A mixed cache memory DIMMs condition has been detected, which
results in a suspended controller state.
LE
Uncertified cache memory DIMM sizes have been detected, which
result in a suspended controller state.
LF
The controller has locked down in a suspended state with limited
symbol support.
LH
A controller firmware mismatch been detected, which results in a
suspended controller state.
LL
The controller cannot access either midplane SBB EEP-ROM, which
results in a suspended controller state.
Ln
A canister is not valid for a controller, which results in a suspended
controller state.
LP
Drive port mapping tables are not detected, which results in a
suspended controller state.
LU
The start-of-day (SOD) reboot limit has been exceeded, which
results in a suspended controller state.
Table 11.15
Supported Diagnostic Lock-Down Codes on the Seven-Segment Display
Diagnostic Code
Description