E2600 DSA E-Series iSCSI Disk Arrays
Replacing a Controller Canister and Related Components | en
121
Bosch Security Systems
Installation Manual
- | V2 | 2012.09
6.
Label each copper cable or fiber-optic cable that is attached to the controller canister so
that you can reconnect the cables correctly after the new controller canister is
reinstalled.
7.
Record the information from the seven-segment display on the rear of the controller-drive
tray.
The display flashes a sequence of codes. To find information about the displayed
diagnostic codes, refer to
Section 11.9 Things to Know – Diagnostic Code Sequences for
the E2600 Controller-Drive Tray, page 84
8.
Take the controller offline, if necessary, and wait for the Controller Service Action
Allowed LED to come on.
9.
Disconnect all of the interface cables and Ethernet cables from the failed controller
canister.
If fiber-optic cables are present, you can use the two release levers to partially remove
the controller canister. Opening these release levers makes it easier to press down on
the fiber-optic cable release tab. If the storage array is running while you perform this
replacement, do not disturb the second controller canister.
10. Remove the failed controller canister.
–
Unlock and pull out the release levers to release the controller canister.
–
Using the release levers and your hands, pull the controller canister out of the
controller-drive tray.
Figure 17.3
Removing and Replacing a Controller Canister
1
Controller Service Action Allowed LED (Blue)
2
Controller Service Action Required LED (Amber)
NOTICE!
Potential degraded performance
To prevent degraded performance, do not twist, fold, pinch, or step on the fiber-optic cables.
Do not bend the fiber-optic cables tighter than a 5-cm (2-in.) radius.