Replacing a Controller Canister in the Controller-Drive Tray | en
97
Bosch Security Systems
Installation Manual
- | V2 | 2012.09
5.
Reinstall the top cover on the new controller canister by sliding it forward until the top
latch covers click.
6.
Remove the controller air blocker.
7.
Slide the new controller canister all the way into the controller-drive tray. Rotate the
release levers towards the center of the controller canister to lock it into place.
8.
Reconnect all of the cables that were disconnected earlier.
9.
Look at the LEDs on the new controller canister to make sure that the new controller is
booting correctly.
The LEDs come on and go off intermittently for approximately 60 seconds (possibly
longer). After this time, you are able to discover the new controller by using the storage
management software.
10. Look at the Controller Service Action Required LEDs, and look at all of the controller-
drive tray’s Service Action Required LEDs. Based on the LED status, perform one of these
actions:
–
All of the Service Action Required LEDs are off, and the Array Management Window
indicates an Optimal status
Go to step 12.
–
Any of the controller-drive tray’s Service Action Required LEDs is on
Check that the controller canister has been installed correctly. Reinstall the control-
ler canister if necessary. Go to step 11.
11. Did this action correct the problem?
–
Yes
Go to step 12.
–
No
If the problem is not resolved, contact your Customer and Technical Support repre-
sentative.
12. Complete any remaining Recovery Guru procedures, if needed.
13. Using the LEDs and the storage management software, check the status of all of the trays
in the storage array.
14. Does any component have a Needs Attention status?
–
Yes
Click the
Recovery Guru
toolbar button in the Array Management Window, and com-
plete the recovery procedure. If the problem is not resolved, contact your Customer
and Technical Support representative.
–
No
Go to step 15.
15. Remove the antistatic protection.
16. Create, save, and print a new storage array profile.
NOTICE!
If your storage array does not have an Optimal status, click the Recovery Guru toolbar button
in the Array Management Window to determine if any other actions are required.