120
en | Replacing a Controller Canister and Related Components
E2600 DSA E-Series iSCSI Disk Arrays
- | V2 | 2012.09
Installation Manual
Bosch Security Systems
4.
Unpack the new controller canister.
–
Set the new controller canister on a flat, static-free surface near the controller-drive
tray with the top cover up.
–
Save all of the packing materials so that you can ship the failed controller canister.
–
Push down the two top cover latch buttons that secure the top cover to the new
controller canister.
–
Remove the top cover by sliding it off the rear of the new controller canister.
Figure 17.1
E2600 Controller Cover, Internal Parts, and Faceplate
5.
Locate the failed controller canister by checking the Controller Service Action Required
LEDs.
If a fault is detected, the amber Controller Service Action Required LED is on. If you can
safely remove the controller canister, the blue Controller Service Action Allowed LED is
on.
Figure 17.2
E2600 Controller Service Action LEDs