122
en | Replacing a Controller Canister and Related Components
E2600 DSA E-Series iSCSI Disk Arrays
- | V2 | 2012.09
Installation Manual
Bosch Security Systems
11. Set the failed controller canister on a flat, static-free surface near the controller-drive
tray with the release levers up. Position the controller canister so you can access the top
cover.
12. Prepare the controller air blocker by removing it from its packaging and folding it inward
at right angles so it is ready to insert into the open controller slot.
Figure 17.4
Controller Air Blocker
13. Insert the controller air blocker into the open controller slot to make sure the correct
airflow is maintained.
Figure 17.5
Inserting the Controller Air Blocker into the Open Controller Slot
14. Press down on both of the top cover latch buttons, and slide the top cover to the rear of
the controller canister. Remove the cover.
1
Release Levers
2
Controller Canister
CAUTION!
Possible equipment damage
The controller slot cannot remain open for more than three minutes because of the possibility
of overheating the equipment. The controller air blocker fills the controller slot so that the
equipment will not overheat.
98022-01