17
Click here to return to >
9.3 Magnetic or Non-Magnetic Module
The magnetic paper path should be cleaned periodically to prevent erratic printer operation.
Cleaning is normally done when you note an increase in VOID tickets.
The cleaning procedure is as follows:
(this is based upon the printer being on and stock loaded
into the printer). You will also need to use part number P63-1000 BOCA Magnetic Encoder Cleaner
Strip.
1.
Depress both the
MENU
and
CHOICES
buttons unit
FACTORY
MENU
appears in the LCD
window or the display starts scrolling through different topics (normally within 6-8 seconds).
2.
Using the
MENU
button scroll down to the
CLEAN MAGNETICS
topic.
3.
Using the
CHOICE
button select
YES
. Once you have done this press the
TEST
button. The
printer will eject ticket stock (if loaded) out of the printer. If needed pull the stock out of the
printer.
The front display will guide you through the rest of the operation.
4. INSERT STRIP -
Insert the P/N P63-1000 BOCA Magnetic Encoder Cleaner Strip into the
printer. Load the cleaner strip just like you would your ticket stock.
5. PRESS TEST -
Press the TEST button at this time. The printer will shuffle the cleaner strip 6
times through the printer and then eject the strip out.
6. REMOVE TICKET -
Remove the cleaning strip as indicated by the display.
7. REVERSE STRIP
–
Rotate the strip around to the unused side.
8. INSERT STRIP
–
Feed the strip back into the printer
9. PRESS TEST -
Press the TEST button at this time. The printer will shuffle the cleaner strip 6
more times through the printer and then eject the strip out.
10. PAPER OUT -
The printer is done running the cleaning routine and you normal ticket stock
may be loaded back into the printer.
Click here to return to >