Working inside right side of cowl, pull up
on lever (
arrow
) and detach right air
intake flap from blower housing.
-
Working in right front of IHKA
housing, detach double pipe (A/C
line) from expansion valve.
Lay double pipe aside.
Plug up open A/C ports.
-
Remove expansion valve mounting
bolts and remove valve.
-
Installation is reverse of removal.
CAUTION!
Always replace O-rings when
reconnecting refrigerant lines.
-
Recharge system following
equipment manufacturer's
instructions.
A/C system fluid specifications
Fluid
Quantity
R-134a refrigerant
740 ± 25 g
(2 lb ± 1 oz.)
Refrigerant oil
PAG oil
A/C evaporator, removing and
installing
-
Following manufacturer's
instructions, connect an approved
refrigerant recovery/recycling
/recharging unit to A/C system and
discharge system.
Heating and Air Conditioning
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/6...
9 of 11
2/25/2009 11:18 PM