door lock.
If the GM receives a request to operate
convenience closing or opening for more
than 110 seconds, the function is
deactivated and a fault code is stored.
Window anti-trap protection
In 4-door models, a rubber pressure
guard located at the top edge of each
door frame consists of two contact strips
that close when subjected to pressure.
When the contact strip closes (for
example, a hand is trapped between the
top of the window and the door frame),
an anti-trap signal is sent to the GM V.
The window immediately (within 10
milliseconds) reverses direction. This
feature does not require initialization.
The E46 pressure sensor finger guard
has a resistance of 3 K
and it is
monitored for open circuit. When
pressed, the monitored resistance
changes to < 1K
. If anti-trap protection
becomes faulty the one touch window
closing will not function.
Window anti-trap protection is only active
in the one touch and convenience close
modes of operation. If the window switch
is pulled and held, anti-trap protection
will not function.
Window motor limit stop
function
If repeated window activation (up/down
cycles) exceeds one minute, the GM V
deactivates the internal relays and
disregards any further up/down
requests. The GM V provides motor
activation after a short duration but not
for the full one minute monitoring cycle.
The GM V monitors the number of times
Door Windows
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/5...
6 of 8
2/25/2009 10:44 PM