DEMOD MODE:
The AQD is capable of locking to a terrestrial (off-
air) 8VSB or CATV QAM Annex B modulated RF input signal. The
selection of the appropriate signal type must be made by the user
to ensure signals are properly identified during a scan. By setting the
Demod Mode the Channel Plan is automatically set to Broadcast for
8VSB signals and Standard CATV for QAM signals or 8VSB signals on
the CATV channel plan.
CHANNEL PLAN:
The Channel Plan mode allows the user to the
select the appropriate frequency mode. This setting alerts the user to
the appropriate center frequency plan the AQD will use during the scan
process.
• The Broadcast option must be selected for off-air 8VSB reception, this
is automatically set if the Demod Mode is set to 8VSB. Reception is
limited to VHF & UHF center frequencies.
• The Standard CATV mode is capable of locking to QAM Annex B and
8VSB signals. This channel plan is automatically set when the QAM B
mode is selected in the Demod Mode command menu. Reception is
limited to CATV center frequencies.
o It is only required to choose the HRC or IRC option when these
frequency off-sets are used with the CATV plan.
➣
NOTE: See Appendix for additional details.
SCAN MENU:
The scan menu command allows the AQD module to
auto search for available programming. It is required that each module
perform a scan in order to function properly. All modules will perform a
scan when the Scan All Modules command is selected.
•
YES –
The YES Command performs a scan on only the selected
active module
•
ALL MODULES –
The ALL MODULES Command performs a new
scan on all of the installed modules
•
STATUS –
The STATUS Command displays the channels found
during the scan process for the selected active module
•
STOP SCAN –
The STOP SCAN Command permits an operator
to stop an in-process scan. It is important to note that once a scan
starts the previously found channel data is immediately erased. If
the scan is stopped, only the completed scan channel data will be
available for selection
•
EXIT –
The EXIT Command exits the scan menu without making
any modifications
Содержание AMM-806
Страница 86: ...79 TVCB PC Installation ...
Страница 93: ...86 SMI Installation Torque Patterns 1 Start Here 2 3 4 5 6 1 Start Here 2 3 4 4 PORT 8 PORT ...
Страница 125: ...118 Fiber Optics Fiber Loss vs Path Length Single Mode 1550 nm ...
Страница 156: ...149 Cable TV Channel Format NTSC NTSC Composite Video Waveform ...
Страница 157: ...150 US Frequency Spectrum ...
Страница 158: ...151 FCC Aeronautical Band Frequencies Used for Communication and Navigation ...
Страница 171: ...164 F C x 32 Temperature Conversion Nomograph C F FAHRENHEIT F CELSIUS C 9 5 C F 32 5 9 KELVIN K K C 273 ...
Страница 175: ...168 Common CATV Symbols ...
Страница 176: ...169 Common CATV Symbols ...
Страница 177: ...170 Digital L Band Distribution Symbols ...
Страница 178: ...171 Digital L Band Distribution Symbols ...
Страница 183: ...176 Typical Cable Attenuation Chart in dB 100 Feet 68 F 20 C ...
Страница 187: ...180 Echo Rating Graph ...
Страница 188: ...181 Signal to Interference Limits Non Coherent Carriers ...
Страница 190: ...183 Heterodyne Modulator Analog ...
Страница 191: ...184 Heterodyne Processor Analog ...
Страница 213: ...206 Multiplexers ...
Страница 215: ...208 Antenna Stacking Methods to Increase Received Signal Level NOTE Refer to Antenna Spacing Chart for dimensions ...
Страница 216: ...209 Antenna Spacing Mounting Channelized Antennas on the Same Mast NOTE Refer to Antenna Spacing Chart for dimensions ...
Страница 285: ...Rev 8 0 ...