SB-170-9 RUS
41
SB-170-9
25
5.4.2 CM-SW-01
Standard for all CSW105 compressors
The compressor module integrates the entire electronic
periphery of the compressor: It allows monitoring the
essential operating parameters of the compressor: mo-
tor and discharge gas temperature, phase and rotation
direction monitoring, oil supply and application limits
and thus protects the compressor from operation under
critical conditions. For further information, see Tech-
nical Information ST-150.
!
!
NOTICE
The compressor module may be damaged or
fail!
Never apply any voltage to the terminals of CN7
to CN12 – not even for test purposes!
The voltage applied to the terminals of CN13
must not exceed 10 V!
The voltage applied to terminal 3 of CN14 must
not exceed 24 V! Do no apply voltage to the
other terminals!
The following components are completely installed and
wired in the state of delivery:
• Slider position indicator.
• Oil monitoring (OLC-D1).
• Solenoid valves for capacity control and V
i
.
• Discharge gas temperature sensor.
• Low pressure and high pressure transmitter.
Modification to these components or their wiring is not
required and should not be done without consulting
BITZER.
The following components are not installed and wired in
the state of delivery and need to be connected:
• Motor temperature monitoring (PTC sensor in motor
winding).
• Phase monitoring (in case of a phase failure or inad-
missibly high phase asymmetry).
The compressor module internally supplies voltage to
the peripheral devices (solenoid valves, oil monitoring
device and slider position indicator) and to the terminal
strips CN7 to CN12.
Please refer to the Technical Information ST-150 for in-
formation on all connections.
5.4.3 SE-i1
This protection device with extended monitoring func-
tions can be used as an option for all HS.53 .. HS.85
compressors and CSH and CSW compressors.
Monitoring functions:
• Temperature monitoring.
• Monitoring of the PTC control circuit to detect any
short-circuit or line break/sensor failure.
• Rotation direction monitoring.
• Monitoring of phase failure and asymmetry.
• Monitoring of the maximum cycling rate.
For further information, see Technical Information
CT-110.
5.4.4 SE-E2
Optional protection device for operation with frequency
inverter and soft starter (for a ramp time shorter than
1 s).
• Dimensions and integration in the control identical to
SE-E1.
• Suitable for all CS. compressors.
• Monitoring functions are basically identical to those
of SE-E1. However, the SE-E2 monitors phase fail-
ure during the entire running time of the compressor.
For further information, see Technical Information
ST-122.
5.4.5 Monitoring of the oil circuit
• For short circuits without liquid injection (LI) for addi-
tional cooling and for small system volume and small
refrigerant charge: Indirect monitoring with oil tem-
perature sensor (standard)
!
!
NOTICE
Lack of oil leads to a too high increase in tem-
perature.
Risk of damage to the compressor!
• For circuits with liquid injection (LI) for additional
cooling and / or for great system volume as well as
parallel compounding: Monitor oil level directly with
opto-electronic oil level monitoring (option), see
chapter Opto-electronic oil level monitoring OLC-D1-
S, page 26. The connection is on the compressor
housing, see chapter Connections and dimensional
drawings, page 14, position 8.
SB-170-9
41
CSH-Verdichter
Gewicht (kg)
Schwerpunkt X (mm)
Schwerpunkt Y (mm)
CSH7583-100(Y)
550
102
25
CSH7593-90Y
530
111
25
CSH7593-110(Y)
560
123
25
CSH7673-70Y
520
120
25
CSH7683-80Y
530
90
25
CSH7693-90Y
535
111
25
CSH8553-80Y
830
103
22
CSH8553-110(Y)
840
115
22
CSH8563-90Y
830
129
22
CSH8563-125(Y)
850
143
22
CSH8573-110Y
840
131
22
CSH8573-140(Y)
860
145
22
CSH8583-125Y
850
98
22
CSH8583-160(Y)
880
108
22
CSH8593-140Y
860
105
22
CSH8593-180(Y)
900
115
22
CSH8673-110Y
850
131
22
CSH8683-125Y
860
98
22
CSH8693-140Y
880
105
22
CSH9553-180(Y)
1280
128
10
CSH9563-160Y
1270
120
10
CSH9563-210(Y)
1300
129
10
CSH9573-180Y
1280
127
10
CSH9573-240(Y)
1310
137
10
CSH9583-210Y
1330
100
10
CSH9583-280(Y)
1360
109
10
CSH9593-240Y
1350
105
10
CSH9593-300(Y)
1380
109
10
CSH95103-280Y
1450
108
10
CSH95103-320(Y)
1480
120
10
CSH95113-320Y
1480
125
10
CSH9663-160Y
1280
120
10
CSH9673-180Y
1290
127
10
CSH9683-210Y
1350
100
10
CSH9693-240Y
1370
105
10
CSH96103-280Y
1450
108
10
CSH96113-320Y
1480
125
10