18
USE AND MAINTENANCE MANUAL
3.2.2
Connection diagram (version with connectors and ABS)
To correctly connect the terminal to the electric mains, proceed as follows:
Connect the terminal to the power supply;
Plug in the terminal using the specific cable.
Figure 3.2-1
–
Connection of the terminal to the electric mains
Key:
1. Terminal with weight display.
2. Power supply.
3. Power cable.
4. Mains socket.
5. 12V/4A power socket.
Power cable
The power cable is generally supplied with IEC 320 socket and 10 A plug (L+N+E).
12V DC power supply
The DD700 weighing terminal can also be powered by a DC source with rated voltage of 12V.
It can be powered by a lead battery or stabilised power supply.
The source must supply 4A.
It must have an external disconnector switch.
Figure 3.2-2
–
Socket
1
2
3
4
5
SHIELD
GND