41
USE AND MAINTENANCE MANUAL
5.2
Functioning of Single weighing operation, Double weighing, Sum
weighing, Load extraction, Unload extraction, CPE functioning,
Manual Selector, Weight Check and Multi-Operator
The type of terminal operation is set while being installed.
The set operating mode is displayed when the terminal is switched on.
5.2.1
Single Weighing Operation (*) (***)
The Single Weighing operation allows you to acquire the gross (or net) weight on the scale and to
view it on the display together with the weighing signals. In this case the possible display formats
are:
15mm Digits, 30mm Digits and Selection.
5.2.2
Double Weighing Operation (*)
The DOUBLE WEIGHING function is used to weigh vehicles, which are weighed before and after
loading to determine the amount of goods transported.
The double weighing operation function can be managed with:
input-output operations;
operations with preset weights.
The input-output operations can be managed with:
automatically assigned data recall (4 digits) for input-output operations (hereinafter abbreviated as
RcD);
plate type data recall (10 characters) for input-output operations with plate settings before each
weighing operation (RcD plate);
without data recall codes for input-output operations with settings of the weight present during
input before each output weighing operation.
The operations with preset weights can be managed with:
data recall (4 digits) for preset weight operations (RcP);
plate type data recall (10 characters) for preset weight operations (RcP plate).
Operation with input and output weighing
Input-output operation requires 2 weighing operations:
input operation during which the weight of the vehicle is acquired as a first weight and
associated with the accessory data (product code, plate and client code) to a recognition code;
output operation during which, the first weight and the accessory data are recalled using the
recognition code and the weight of the vehicle is acquired as a second weight and the
difference is calculated (net weight).
The recognition code used during the input-output operation can be a data recall type of code (RcD 4
digits) or plate type of code (10 characters RcD plate).
The two types of codes distinguish two different ways of performing the input operations.
Input/output operation with Data Recall
This type of operation is enabled during installation.
The input and output operation phases do not have to be consecutive, and the difference between
the two input and output weights can be calculated on the second.
Input operations
With every incoming print, the terminal attributes and prints a code (Rcd code) which, if set before