20
USE AND MAINTENANCE MANUAL
DANGER
Check that:
the voltage and frequency of the terminal's electric power line are as indicated on the
stamped plate at the bottom of the terminal;
the socket the terminal is plugged into is earthed;
the warning and danger plates are applied to the casing of the terminal;
if not, notify maintenance personnel or directly notify our Assistance Service.
Wiring scale cable
To connect the terminal to the weighing platform, it is normally supplied with a pre-wired cable.
Key
1. Male 9/15 pin cup connector
2. Nut
3. Bottom side of terminal
4. Cable gland
5. Shielded shell (cap) with stamped screws
Figure 3.2-5
–
Load cell connection
Insert the 9/15 pin connector into the specific scale inlet
Secure the cable gland with the nut.
Refit the shell with the perforated stamped screws.
Insert the connector at the bottom of the CPU container.
The connection could be different depending on the type of load cell mounted on the weighing
platform: analogue or digital. In the event of a duplex scale, scale A must be connected to connector
JBIL1 and scale B to connector JBIL2.
WARNING
The cable shield must always be connected to the metal protective cap of the 9/15 pin connector.
Do not insert the connection cable to the weighing platform on paths together with direct power
driven cables.