INSTALLATION MANUAL
Logic
Definition
Default
Cross out
setting
used
Optional extras
EXPI1
Configuration of
EXPI1 input on
input-output ex-
pansion board.
1-2
1
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the movement stops.
12
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the movement stops.
13
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is switched
automatically to safety device test input, EXPFAULT1.
14
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/output
expansion board is switched automatically to safety device test input, EXPFAULT1
15
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/output expansion
board is switched automatically to safety device test input, EXPFAULT1
16
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched auto-
matically to safety device test input, EXPFAULT1.
17
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the movement
stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input, EXPFAULT1.
18
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the movement
stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test input, EXPFAULT1.
EXPI2
Configuration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the movement stops.
12
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the movement stops.
EXPO1
Configuration of
EXPO2 output
on input-output
expansion board
4-5
11
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
EXPO2
Configuration of
EXPO2 output
on input-output
expansion board
6-7
11
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
12
Output configured as Antitampering
13
Output configured as Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
TRAFFIC LIGHT
PREFLASHING
Traffic light pre-
flashing
0
0
Pre-flashing switched off.
1
Red lights flash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red
light
0
0
Red lights off when gate closed.
1
Red lights on when gate closed.
40 -