INSTALLATION MANUAL
2) GENERAL INFORMATION
The
LEO B CBB 3 230 L02- LEO B CBB 3 120 F02
control panel comes with
standard factory settings. Any change must be made using the programmer with
built-in display or universal handheld programmer. The Control unit completely
supports the EELINK protocol.
Its main features are:
- Control of 1 single-phase motor
- Electronic torque control
- Obstacle detection (only on LEO B CBB 3 230 L02 e LEO B CBB 3 120 F02)
- Separate inputs for safety devices
- Configurable command inputs
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77. If the above-
mentioned terminals are being used, remove the relevant jumpers.
LEO B CBB 3 230 L02
LEO B CBB 3 120 F02
Power supply
220-230V~ 50Hz/60Hz
120V~ ±10% 50Hz/60Hz
Obstacle
detection with
encoder
Present
Present
Output for
terminals 26-27:
N.O. contact
(24V~/0,5A)
AUX3 configurable
Output for audible signal
TESTING
The
LEO B CBB 3 230 L02- LEO B CBB 3 120 F02
panel controls (checks) the
start relays and safety devices (photocells) before performing each opening
and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
220-230V~ 50Hz/60Hz
(LEO B CBB 3 230 L02)
120V~ ±10% 50Hz/60Hz
(LEO B CBB 3 120 F02)
Low voltage/mains insulation
> 2MOhm 500V
Operating temperature range
-20 / +55°C
Thermal overload protection
Built into motor
Dielectric rigidity
mains/LV 3750V~ for 1 minute
Maximum motor power
750W
Accessories power supply
24V~ (demand max. 1A)
24V~safe
AUX 0
220-230V~N.O. (40W max)
(LEO B CBB 3 230 L02)
powered contact
120V~N.O. (40W max)
(LEO B CBB 3 120 F02)
powered contact
AUX 3/ Output for audible signal
NO contact (24V~/max.0,5A)
Dimensions
146x170x60mm
Fuses
see
Fig. B
N° of combinations
4 billion
Max.n° of transmitters that can be memorized 63
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. B
WARNINGS -
When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
Terminal
Definition
Description
Po
w
er
supply
L
LINE
Single-phase power supply
220-230V
~
50/60Hz
, with earth cable
(LEO B CBB 3 230 L02).
Single-phase power supply 120V~ ±10%, 50-60Hz, with earth cable
(LEO B CBB 3 120 F02).
N
NEUTRAL
GND
EARTH
M
ot
or
10
START + CAP
Motor connection.
START + CAP Motor Start and capacitor
COM Motor Common
START + CAP Motor Start and capacitor
11
COM
12
START + CAP
Au
x
20
AUX 0 - POWERED CON-
TACT 220 230V~
(LEO B CBB 3 230 L02)
POWERED CONTACT 120V~
(LEO B CBB 3 120 F02)
AUX 0 configurable output - Default setting FLASHING LIGHT.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / ANTITAMPERING / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to “AUX output configuration” table.
21
26
AUX 3 - FREE CONTACT
(N.O.)
A U X 1 c o n f i g u r a b l e o u t p u t - D e f a u l t s e t t i n g Z O N E L I G H T O u t p u t .
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/
STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING
LIGHT AND MAINTENANCE /ANTITAMPERING / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to “AUX output configuration” table.
27
M
ot
or
limit swit
ch
1 (mo
del not
UL
TR
A)
41
+ REF SWE
Limit switch common
42
SWC
Closing limit switch SWC (N.C.). (Do not connect or jump if there is the magnetic limit switch)
43
SWO
- Opening limit switch SWO (N.C.). (NDo not connect or jump if there is the magnetic limit switch)
M
ot
or
magnetic
limit swit
ch 1
JP32
Magnetic limit switch connection
A
cc
essories po
we
r
supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
Commands
60
Common
IC 1 and IC 2 inputs common
61
IC 1
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
62
IC 2
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
63
Common
IC 3 and IC 4 inputs common
64
IC 3
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
65
IC 4
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
WIRING AND TERMINAL BOARD CONFIGURATION
34 -
LEO B CBB 3 230 L02 - LEO B CBB 3 120 F02
D812916 00100_01