INSTALLATION MANUAL
Parameter
min. max. Default Personal
Definition
Description
OP.FORCE
1
99
41
(LEO B CBB
3 230 L02)
75
(LEO B CBB
3 120 F02)
Leaf force during opening
[%]
Force exerted by leaf/leaves during opening.
Only for LEO B CBB 3 230 L02:
This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated),
before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
CLS.FORCE
1
99
41
(LEO B CBB
3 230 L02)
75
(LEO B CBB
3 120 F02)
Leaf force during closing
[%]
Force exerted by leaf/leaves during closing.
Only for LEO B CBB 3 230 L02:
This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated),
before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
OP.SLWD.
FORCE
1
99
75
Leaf/leaves force during
opening during
slow-down
“Force exerted by leaf/leaves during opening at slow-down speed.”
Only for LEO B CBB 3 230 L02:
This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated),
before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
CLS.SLWD.
FORCE
1
99
75
Leaf/leaves force during
closing during slow-down
[%]
“Force exerted by leaf/leaves during closing at slow-down speed. “
Only for LEO B CBB 3 230 L02:
This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated),
before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
BRAKE
0
99
0
Braking [%]
Percentage of braking applied to stop motion of motor(s).
Maintenance
0
250
0
Programming number of
operations for maintenance
threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance
will be reported on the AUX output configured as Maintenance or Flashing Light
and Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE “B” - LOGICS
(
LOGIC
)
Logic
Definition
Default
Cross out
setting
used
Optional extras
TCA
Automatic Closing
Time
0
0
Logic not enabled
1
Switches automatic closing on
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
STEP-BY-STEP
MOVEMNT
Step-by-step
movement
0
0
Inputs configured as Start E, Start I, Ped oper-
ate with 4-step logic.
step-by-step mov.
2 STEP
3 STEP
4 STEP
CLOSED
OPENS
OPENS
OPENS
DURING
CLOSING
STOPS
OPEN
CLOSES
CLOSES
CLOSES
DURING
OPENING
STOP + TCA STOP + TCA
AFTER STOP
OPENS
OPENS
OPENS
1
Inputs configured as Start E, Start I, Ped oper-
ate with 3-step logic. Pulse during closing
reverses movement.
2
Inputs configured as Start E, Start I, Ped op-
erate with 2-step logic. Movement reverses
with each pulse.
Encoder
Encoder
2
0
Operation with encoder disabled
WARNING
This setting fully disables the anti-crush safety device,
with serious safety risks.
Install active safety edges on closing and opening or switch
to deadman operation. (see Deadman logic)
WARNING: Check that the force of impact measured at
the points provided for by standard EN 12445 is lower
than the value laid down by standard EN 12453.
WARNING: Setting sensitivity incorrectly can
result in damage to property and injury to people
and animals.
1
Operation with encoder used as position sensor for ac-
quiring slow-down distances. - Gate detection locked out.
Manual setting of “opening force”, “closing force”, “opening
slow-down force” and “closing slow-down force” parameters.
2
Only active on LEO B CBB 3 230 L02
Automatic mode with encoder: slow-down and obstacle
detection performed by means of encoder. Option of using
“autoset” function. Adjustment of obstacle detection sen-
sitivity (opening force, closing force, opening slow-down
force, closing slow-down force parameters) (default setting).
PRE-ALARM
Pre-alarm
0
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
LEO B CBB 3 230 L02 - LEO B CBB 3 120 F02
-
37
D812916 00100_01
ENGLISH