HOLD-TO-RUN
Deadman
0
0
Pulse operation.
1
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
2
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman mode is enabled
which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
IBL OPEN
Block pulses du-
ring opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
|IBL TCA
Block pulses
during TCA
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
IBL CLOSE
Block pulses
during closing
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode (Fig.G Rif. 1).
1
Opens in other direction to standard operating mode (Fig. G Rif.2)
SAFE 1
Configuration
of safety input
SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
SAFE 2
Configuration
of safety input
SAFE 2.
74
6
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
SAFE 3
Configuration
of safety input
SAFE 3.
77
2
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2
(Inactive on SAFE 3).
9*
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
10*
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
movement stops.
11*
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the movement stops.
(Inactive on SAFE 3).
12*
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
13*
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
movement stops.
14*
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement stops.
(Inactive on SAFE 3).
IC 1
Configuration of
command input
IC 1.
61
0
0
Input configured as Start E.
1
Input configured as Start I.
IC 2
Configuration of
command input
IC 2.
62
4
2
Input configured as Open.
3
Input configured as Close.
IC 3
Configuration of
command input
IC 3.
64
2
4
Input configured as Ped.
5
Input configured as Timer.
IC 4
Configuration of
command input
IC 4.
65
3
6
Input configured as Timer Pedestrian.
1ch
Configuration
of the 1st radio
channel command
0
0
Radio control configured as START E.
1
Radio control configured as Start I.
2
Radio control configured as Open.
2ch
Configuration
of the 2nd radio
channel command
9
3
Radio control configured as Close
4
Radio control configured as Ped
5
Radio control configured as STOP
6
Radio control configured as AUX0 **
3 ch
Configuration
of the 3rd radio
channel command
2
7
Not used
8
Not used
9
Radio control configured as AUX3 **
4 ch
Configuration
of the 4th radio
channel command
5
10
Radio control configured as EXPO1 **
11
Radio control configured as EXPO2 **