VisiPC Software Manual Part 1 – Visilynx 3 Configurator
INS00231 Issue 4 Page 80 of 88
4.19.1 DVR Default Input Settings
‘DVR Default Input Settings’ maps the six physical DVR inputs to the six recording channels.
Note: The settings on this screen are only used by a trainborne rack system to configure its
internal DVR.
This screen will only appear if you have defined one or more camera maps in the ‘Global
System Settings’ screen (see page 21). Trainborne racks normally have two maps set.
When a trainborne rack receives a ‘Wakeup’ remote control command, Map 1 or 2 is
selected according to a combination of the Direction flag in the command and the train-end
switch:
Direction flag
Train end switch
Selected map
0 (forward)
A
1
0 (forward)
B
2
1 (reverse)
A
2
1 (reverse)
B
1
The selected map determines how the DVR connects its record channels to the input
channels:
•
Map 1: Record channels 1-6 are connected to ‘Inputs for Map 1’ inputs.
•
Map 2: Record channels 1-6 are connected to ‘Inputs for Map 2’ inputs.
Figure 73 VCR/DVR Default Input Settings Screenshot
•
Inputs for Map 1 (2)
: Enter the required physical input number (1-6) against each of the
six listed record channel numbers. If “---“ is selected, no recording will be made on that
channel.