3522.5-0000010
РЭ
42
Using the mode of choosing between inducible parameters the customer can acti-
vate, if necessary, displaying of various engine parameters on the screen as per table 2.5.
The mode of parameter choosing is activated after activation of the button panel with
short-time pressing the button 5. Sequential pressing the button 1 changes the parameters
displayed in the upper left corner, pressing the button 2 changes the parameters in the up-
per right corner, button 3 – in the lower left corner, button 4 – in the lower right corner. The
parameter choosing mode is exited with short-time pressing the button 5.
As the button panel has been activated pressing the button 3 activates graphical
displaying of parameters in the course of time (functions as parameter analogue recorder).
The required parameters are chosen with a sequential pressing the button 3 as per
table 2.5.
A temporary net can be adjusted in a configuration menu from 2, 10 or 30 min. to 1,
2, 4 or 8 hours. To enter the configuration menu it is necessary to press the button 5 for
more than 3 sec., after that enter PIN-code. After the PIN-code has been entered it is pos-
sible to choose metric and British units of measurement in this menu, among available
languages it is possible to choose English, Spanish, Swedish, French, German, Italian,
Dutch, Portuguese and Russian.
ATTENTION: ONLY DEALERS ARE AUTHORISED TO ENTER PIN-CODE AND
CHANGE SETTINGS OF CONFIGURATION MENU!
When errors (faults) are detected during operation the monitor produces a sound
signal and a rhombic flashing window with an exclamation mark appears on the screen.
After the button panel has been activated a list of active errors (faults) is invoked
with the button 4. Moving over the list is carried out with the button 1 and 2. The errors, the
reception of which has not yet been confirmed, are printed in grey buttons on a black
background.
To exit displaying of the lift of active errors it is necessary to confirm reception of all
errors by pressing the button 3. After that confirmation errors are printed in black buttons
on a grey background.
After the fault has been eliminated active errors pass automatically to the lift of inac-
tive errors.
The list of inactive errors is activated with pressing and holding the button 4. The
engine electronic control unit provides a possibility to delete the information on stored er-
rors, it is possible to erase them when they are on the screen, to do this it is required to
press and hold the button 3.
https://tractormanualz.com/
Содержание 3522.5
Страница 1: ...BELARUS 3522 5 3522 5 0000010 OM OPERATOR S MANUAL 2011 https tractormanualz com ...
Страница 9: ...3522 5 0000010 РЭ 10 https tractormanualz com ...
Страница 17: ...3522 5 0000010 РЭ 18 Figure 1 1 2 Tractor BELARUS 3522 5 left and right views https tractormanualz com ...
Страница 129: ...3522 5 0000010 РЭ 130 Figure 3 9 2 Brakes control scheme 15 50 mm fluid level https tractormanualz com ...
Страница 314: ...3522 5 0000010 OM 315 Figure 7 2 1 Harness of RLL control system in respect of cab https tractormanualz com ...
Страница 316: ...3522 5 0000010 OM 317 Figure 7 2 3 Electrical circuit diagramm of RLL control system https tractormanualz com ...
Страница 335: ...3522 5 0000010 OM 336 Service bulletins https tractormanualz com ...
Страница 337: ...3522 5 0000010 OM 375 Annex B compulsory https tractormanualz com ...
Страница 338: ...3522 5 0000010 OM 376 Annex B obligatory https tractormanualz com ...
Страница 339: ...3522 5 0000010 OM 377 Annex C obligatory https tractormanualz com ...
Страница 340: ...3522 5 0000010 РЭ Annex D obligatory 378 https tractormanualz com ...