3522.5-0000010 OM
272
6.4.1.10 Task 9. Inspect/clean air conditioner condenser and oil cooling radiator of
HLL and HSC systems
Check cleanness air conditioner condenser core and oil cooling heat radiator of HLL
and HSC systems. If they are clogged, it is necessary to clean the condenser and the ra-
diator with a compressed air. Open the hood and direct an air flow perpendicular to the
condenser plane from top downward. Jammed finning must be planished by means of
special comb or plastic (wooden) plate. In case of severe condenser clogging rinse it with
hot water under pressure not more than 0.2 MPa and blow it off by a compressed air.
- condenser cores must be cleaned both from the hood mask side and from the en-
gine fan side. To do this, heft the air conditioner condenser as indicated in figure 6.4.1.11.
USE OF CORROSIVE DETERGENT COMPOSITION IS FORBIDDEN!
6.4.1.11 Task 10. Inspect/clean the engine water radiator and the engine CAC-
radiator.
Check cleanness of the engine CAC-radiator 1 core (Figure 3.1.3). In case it is
clogged perform the following actions:
- turn off the two air conditioner condensers screws fastening it to the CAC lifting
mechanism;
- pull the lower part of the condenser and anchor it in hefted position by means of
limit stop, placed to the right along the tractor run;
- carry out the CAC-radiator cleaning with the compressed air. Direct an air flow
perpendicular to the CAC-radiator plane from top downward. In case of severe CAC-
radiator clogging rinse it with hot water under pressure not more than 0.2 MPa and blow it
off by a compressed air;
- put the air conditioner condenser back;
- unscrew two winged nuts 10 for 3…5 turns;
- by means of lifting mechanism heft the air conditioner condenser, oil cooling sys-
tem of HLL and HSC systems, CAC, and clean the water radiator with a compressed air.
Direct an air flow perpendicular to the water radiator from top downward. In case of severe
water radiator clogging rinse it with hot water under pressure not more than 0.2 MPa and
blow it off by a compressed air;
- radiator cores must be cleaned both from the hood mask side and from the engine
fan side;
- put the radiators and tighten the winged nut up.
ALKALINE SOLUTIONS AND CORROSIVE DETERGENT COMPOSITION MUST
NOT BE USED!
6.4.1.12 Task 11. Check/rinse of gripper tools of FLL and RLL
Check the pockets where the hinged joint locking mechanism in the gripper tools 2
(Figure 6.4.4) of the RLL. In case of dirt accumulation, clear the internal pockets and rinse
it with water.
1 – link; 2 – gripper tool.
Figure 6.4.4 – Gripper tool of RLL (FLL)
https://tractormanualz.com/
Содержание 3522.5
Страница 1: ...BELARUS 3522 5 3522 5 0000010 OM OPERATOR S MANUAL 2011 https tractormanualz com ...
Страница 9: ...3522 5 0000010 РЭ 10 https tractormanualz com ...
Страница 17: ...3522 5 0000010 РЭ 18 Figure 1 1 2 Tractor BELARUS 3522 5 left and right views https tractormanualz com ...
Страница 129: ...3522 5 0000010 РЭ 130 Figure 3 9 2 Brakes control scheme 15 50 mm fluid level https tractormanualz com ...
Страница 314: ...3522 5 0000010 OM 315 Figure 7 2 1 Harness of RLL control system in respect of cab https tractormanualz com ...
Страница 316: ...3522 5 0000010 OM 317 Figure 7 2 3 Electrical circuit diagramm of RLL control system https tractormanualz com ...
Страница 335: ...3522 5 0000010 OM 336 Service bulletins https tractormanualz com ...
Страница 337: ...3522 5 0000010 OM 375 Annex B compulsory https tractormanualz com ...
Страница 338: ...3522 5 0000010 OM 376 Annex B obligatory https tractormanualz com ...
Страница 339: ...3522 5 0000010 OM 377 Annex C obligatory https tractormanualz com ...
Страница 340: ...3522 5 0000010 РЭ Annex D obligatory 378 https tractormanualz com ...