2022.3-0000010 OM
323
of dismounting it from the tractor. If carrying out ad-
justments failed to eliminate the
-01 sensor failure,
it is required to mount a new
-01 sensor on the trac-
tor and adjust it properly.
3. Failure (break) in the cable in the sensor circuit.
Check the cable according to the diagram (Figure
7.13.2)
Table 7.13 finished
Error code
Description, anticipated
problem
Failure inspection method
23
Failure of the control
panel. Potentiometer of
the depth control lever is
damaged
Check the reliability of the control panel sockets and
electronic unit connection, and check the cable for
mechanical damage. Check the voltage output ac-
cording to the electrical connections diagram (Figure
7.13.2)
24
Failure of the control
panel. The RLL upper-
most end position lever
is damaged
Check the reliability of the control panel sockets and
electronic unit connection, and check the cable for
mechanical damage. Check the voltage output ac-
cording to the electrical connections diagram (Figure
7.13.2)
28
Failure of the control
panel. The RLL operation
lever 7 (Figure 2.15.1) is
damaged
Check the reliability of the control panel sockets and
electronic unit connection, and check the cable for
mechanical damage. Check the voltage output ac-
cording to the electrical connections diagram (Figure
7.13.2)
31
Failure of the right force
sensor
10
(
Figure
3.18.1
)
. Cable breaking
or the sensor short circuit
32
Failure of the left force
sensor
11
(
Figure
3.18.1
)
. Cable breaking
or the sensor short circuit
To check if it is failure of the sensor or the cable (in
circuit to the sensor), disconnect the sockets from the
cable to the sensors (left and right) and interchange
their positions (the socket from the left sensor to the
right sensor channel and the socket from the right
sensor to the left sensor channel). If after that the er-
ror code has changed (31 was replaced by 32 or 32
was replaced by 31), that means that the sensor is
out of order, if the error code is still the same, that
means that the cable is out of order
Easy defects
34
Failure of the control
panel. Potentiometer of
the RLL speed control
lever is damaged
Check the reliability of the control panel sockets and
electronic unit connection, and check the cable for
mechanical damage. Check the voltage output ac-
cording to the electrical connections diagram (Figure
7.13.2)
36
Failure of the control
panel. Potentiometer of
tilling modes combination
lever: force mode – point-
to-point operation mode
Check the reliability of the control panel sockets and
electronic unit connection, and check the cable for
mechanical damage. Check the voltage output ac-
cording to the electrical connections diagram (Figure
7.13.2)
Code is
not dis-
played
Spontaneous lift of RLL
after the engine start
“Lift” forward/reverse spool was blocked abroach.
Disconnect the cable sockets from the “Lifting” and
“Lowering” solenoids. If the failure is still displayed,
eliminate the failure in the RLL hydraulic system.
https://tractormanualz.com/
Содержание 1822.3
Страница 1: ...BELARUS 1822 3 1822 3 2022 3 2022 3 2022 3 0000010 OM OPERATOR S MANUAL 2012 https tractormanualz com ...
Страница 325: ...2022 3 0000010 OM 324 Figure 7 13 1 RLL electronic control system cables https tractormanualz com ...
Страница 326: ...2022 3 0000010 OM 325 Figure 7 13 2 Electrical circuit diagram of RLL control system https tractormanualz com ...
Страница 353: ...2022 3 0000010 OM 352 SERVICE BULLETINS https tractormanualz com ...
Страница 354: ...2022 3 0000010 OM 348 Annex compulsory https tractormanualz com ...
Страница 356: ...2022 3 0000010 OM 350 Annex B compulsory https tractormanualz com ...