EN
Installation and operating manual
DRYPOINT
®
AC 410 – 495 | DRYPOINT
®
AC 410 – 495 MS
49
8.2. Troubleshooting of BEKOMAT
®
20 FM
Symptom
Possible cause
Remedy
All LEDs off
Fault in power supply
Power supply PCB defective
Control PCB defective
Check voltage against that specified on
the type plate
Check external and internal wiring
Check plug connections
Inspect PCBs for damage
TEST button pressed, but no
condensate discharge
Feed/drain line blocked or closed
Wear (seals, valve core, diaphragm)
Control PCB defective
Solenoid valve defective
Pressure below minimum pressure
Pressure above maximum pressure
Check feed/drain lines
Replace wearing parts
Check whether the valve opens with an
audible click sound (repeatedly press
TEST button)
Inspect PCBs for damage
Check operating pressure; if necessary,
install low-pressure or vacuum drain
Condensate is only discharged while
TEST button is pressed
Insufficient feed line incline; cross-
section too small
Excessively high condensate volume
Sensor tube very dirty
Install feed line at an incline
Install venting line
Clean sensor tube
Device constantly blows off air
Control air line blocked
Wear (seals, valve core, diaphragm)
Clean entire valve unit
Replace wearing parts
Clean sensor tube
9. Shutting down plant
For plants that are run in continuous mode, perform the following steps to shut down the plant:
1. Close the shut-off fittings behind the plant (valve B, see figures "Bypass line" on page
2. Do not shut down the control unit until both adsorbers are fully regenerated.
3. Shut down the control unit by disconnecting the control box from the power supply.
NOTE
Shutting down
•
After shutting down, no compressed air must flow through the plant, as this would result in
an overload of the adsorbent, so that it can no longer be regenerated by the dryer system.
• For plants that are operated in systems with discontinuous compressed air consumption,
you must install a control suitable for intermittent operation.