1.4. Transport and storage
DANGER
External forces and torques
The plant must be protected against external forces and torques, as these could cause
damage, leading to leakage or even malfunction of the plant.
•
• Ensure that no external forces and torques are transferred to the plant through the on-
site piping system. Otherwise, the permissible load on the system might be exceeded.
If necessary, the plant operator must carry out tests or make modifications to the on-site
installations.
• The adsorption dryer must be protected against vibration caused by other units. If
necessary, the operator must take suitable measures to prevent the propagation of
vibration.
WARNING
Uneven load distribution
There is a high risk of serious injury when the plant is being transported with lifting gear.
• The angle between the perpendicular and the ropes must at all times be greater than 45°.
Otherwise, the piping system might be damaged so that it is no longer tight, and there is a
risk of serious malfunction of the plant.
• Never lift the plant by the pipes. Otherwise, the piping system might be damaged so that it
is no longer tight, and there is a risk of serious malfunction of the plant.
NOTE
Labels on packaging
Observe the labels on the packaging.